0800MD-1-003

0800MD-1-003

$191.29
  • Description:PWR XFMR TOROIDAL 800VA CHAS MT
  • Series:MD
  • Mfr:Talema Group LLC
  • Package:Box

SKU:e72695b3e98b Category: Brand:

  
  • Quantity
    • -
    • +
  •    
ChipApex WhatsApp

Consult the customer manager about the wholesale price.

consultation hotline:86-132-6715-2157

email:chipapexlimited@gmail.com
Contact the product manager for consultation. One-stop consultation is available.


Do you want a lower wholesale price? Please send us your inquiry and we will reply immediately.

*
*
*
*
Submitting!
Submission successful!
Submission failed!
Email error!
Phone number error!

Product Detailed Parameters

  • Description:PWR XFMR TOROIDAL 800VA CHAS MT
  • Series:MD
  • Mfr:Talema Group LLC
  • Package:Box
  • Type:Toroidal
  • Voltage - Primary:100V, 120V, 200V, 240V
  • Voltage - Secondary (Full Load):Parallel 120V, Series 240V
  • Current - Output (Max):Parallel 6.67A, Series 3.33A
  • Primary Winding(s):Dual, Multiple Taps
  • Secondary Winding(s):Single, Multiple Taps
  • Center Tap:No
  • Power - Max:800VA
  • Mounting Type:Chassis Mount
  • Termination Style:Wire Leads
  • Size / Dimension:165.00mm Dia x 72.00mm W
  • Height - Seated (Max):-
  • Voltage - Isolation:5000Vrms
  • Weight:14 lbs (6.4 kg)

Download product information

0800MD-1-003

Buying Guide
Summary

Talema Group LLC 0800MD-1-003 is selected in Power Transformers category when protection behavior and transient response must be validated under realistic load steps. Key specs include Description (PWR XFMR TOROIDAL 800VA CHAS MT), Mounting (Chassis Mount), and Packaging (Box).

Selection Notes
  • For 0800MD-1-003, verify the supply current (Parallel 6.67A, Series 3.33A) under your operating conditions and modes.
  • Verify Termination Style (Wire Leads) and compare it against your reference design limits.
  • Verify the mounting type (Chassis Mount) fits your manufacturing and inspection workflow.
Alternates & Substitutions
  • For Power Transformers, treat alternates as an integration task and validate the assumptions that matter on the assembled system.
  • Start with mechanical equivalence and keep mounting Chassis Mount, packaging Box aligned so the alternate is footprint-safe.
  • For power parts, match input/output limits first, then validate stability, protection behavior, and thermals under load steps and transients.
  • Compare not just numbers but also the conditions: rails, loads, timing, and temperature points behind the spec table.
FAQ

Who is the manufacturer of 0800MD-1-003?
Talema Group LLC

Any tips for derating and validation for 0800MD-1-003?
Validate at worst-case temperature and load, confirm thermal headroom, and check protection and startup behavior with margin.

Can you confirm the Size / Dimension for 0800MD-1-003?
165.00mm Dia x 72.00mm W

What Voltage - Secondary (Full Load) is listed for 0800MD-1-003?
Parallel 120V, Series 240V

Application Scenarios

Talema Group LLC 0800MD-1-003 shows up under Power Transformers when designers want a well-bounded, datasheet-driven building block instead of a fragile board-level workaround. Engineers generally evaluate efficiency, thermal rise, transient response, EMI behavior, and fault handling to protect sensitive downstream circuits. They frequently integrate protections such as OCP/OVP/UVLO/OTP and telemetry features that simplify system monitoring and compliance. In battery-powered sensors and wearables, low standby current and clean switchover behavior protect both runtime and stored data. In practice, within PoE-powered equipment, robust power management ensures stable operation under cable loss, thermal constraints, and varying supply headroom. Across instrumentation, clean rails reduce measurement noise so converter and analog front-end accuracy is not limited by supply ripple. In real deployments, for fielded equipment, repeatability and documentation often matter as much as peak performance, and this approach supports both.

Compatibility Advice
  • In board-level integration, validate magnetic components under the real waveform so saturation and audible noise are not discovered late before release to production.
  • To avoid late surprises, validate parasitics and resonance in the real layout so high-frequency behavior does not create surprises in EMI and stability across temperature and supply corners.
  • On the assembled PCB, validate derating under voltage and ripple current so passives do not run at the edge in continuous duty. This keeps qualification evidence reproducible later.
Project Fit
  • Good fit when you can verify Talema Group LLC 0800MD-1-003 for Power Transformers integration in the final enclosure, and you can validate ripple and transient response at the point of load.
  • Poor fit when frequency behavior and parasitics are not measured, so stability and noise outcomes are uncertain, because the remaining risk is system-level and cannot be bounded by datasheet checks alone.
0800MD-1-0030800MD-1-003
$191.29
Buy Now