NPP-301B-100AT

NPP-301B-100AT

$5.18
  • Description:SENSOR 15PSIA 0.08" .06V
  • Series:NPP-301
  • Mfr:Amphenol Advanced Sensors (NovaSensor)
  • Package:Tape & Reel (TR)

SKU:c5bbd8a246ad Category: Brand:

  
  • Quantity
    • -
    • +
  •    
ChipApex WhatsApp

Consult the customer manager about the wholesale price.

consultation hotline:86-132-6715-2157

email:chipapexlimited@gmail.com
Contact the product manager for consultation. One-stop consultation is available.


Do you want a lower wholesale price? Please send us your inquiry and we will reply immediately.

*
*
*
*
Submitting!
Submission successful!
Submission failed!
Email error!
Phone number error!

Product Detailed Parameters

  • Description:SENSOR 15PSIA 0.08" .06V
  • Series:NPP-301
  • Mfr:Amphenol Advanced Sensors (NovaSensor)
  • Package:Tape & Reel (TR)
  • Applications:Board Mount
  • Pressure Type:Absolute
  • Operating Pressure:15PSI (103.42kPa)
  • Output Type:Wheatstone Bridge
  • Output:0 mV ~ 60 mV (3V)
  • Accuracy:±0.2%
  • Voltage - Supply:3V ~ 10V
  • Port Size:Male - 0.08" (2.04mm) Tube, Dual
  • Port Style:Barbless
  • Features:-
  • Termination Style:Gull Wing
  • Maximum Pressure:45PSI (310.26kPa)
  • Operating Temperature:-40°C ~ 125°C
  • Mounting Type:Surface Mount
  • Package / Case:8-SOIC (0.154", 3.90mm Width)
  • Supplier Device Package:-

Download product information

NPP-301B-100AT

Buying Guide
Summary

Amphenol Advanced Sensors (NovaSensor) NPP-301B-100AT is used in Pressure Sensors, Transducers category where placement, interface fit, and operating envelope drive measurement reliability. Key specs include Description (SENSOR 15PSIA 0.08" .06V), Output type (Wheatstone Bridge), Temperature (-40°C ~ 125°C), Package/case (8-SOIC (0.154", 3.90mm Width)), and Mounting (Surface Mount).

Selection Notes
  • For NPP-301B-100AT, ensure the output type (Wheatstone Bridge) is compatible with the downstream interface.
  • Confirm the operating temperature range (-40°C ~ 125°C) meets your deployment conditions.
  • Verify Accuracy (±0.2%) and compare it against your reference design limits.
  • Make sure the mounting type (Surface Mount) matches how the part will be installed and inspected.
Alternates & Substitutions
  • In Pressure Sensors, Transducers, confirm that alternates preserve startup states and fault behavior so system behavior does not change quietly.
  • Always compare the datasheet test conditions behind key specs (load, frequency, temperature) to avoid swapping in a part that was characterized differently.
  • Start with mechanical equivalence and keep package/case 8-SOIC (0.154", 3.90mm Width), mounting Surface Mount, packaging Tape & Reel (TR) aligned so the alternate is footprint-safe.
  • Confirm compliance/qualification needs (for example RoHS/REACH or grade) before approving a second source for production.
FAQ

How do I validate sensor performance for NPP-301B-100AT?
Test with real fixtures and environmental conditions, then confirm calibration, drift, and noise behavior meet your requirements.

Which operating temperature range is listed for NPP-301B-100AT?
-40°C ~ 125°C

Can you confirm the Output for NPP-301B-100AT?
0 mV ~ 60 mV (3V)

What is the Port Size of NPP-301B-100AT?
Male - 0.08" (2.04mm) Tube, Dual

Application Scenarios

When sourcing Amphenol Advanced Sensors (NovaSensor) NPP-301B-100AT for Pressure Sensors, Transducers, engineers typically focus on de-risking integration and keeping validation repeatable. In practice, pressure sensing emphasizes porting, response time, drift, and compensation so accuracy remains stable under real mechanical and thermal stress. Designers often evaluate response time, drift, contamination resistance, and compensation so readings stay meaningful over time. Integration often involves placement strategy, airflow considerations, and calibration workflows tied to the target environment. In data centers, distributed sensing improves hot-spot detection in constrained airflow channels between racks. In industrial safety, gas and smoke sensing is treated as a reliability problem, so calibration and drift behavior are validated over time. Across smart buildings, environmental sensors drive HVAC optimization in ceiling nodes exposed to dust and changing airflow patterns. With the boundaries defined early, teams can validate faster and keep failure modes more predictable.

Compatibility Advice
  • In practice, check filtering and bandwidth choices so noise, latency, and stability align with the real control loop or measurement method before committing to volume builds.
Project Fit
  • Good fit when you can test and document Amphenol Advanced Sensors (NovaSensor) NPP-301B-100AT for Pressure Sensors, Transducers integration with production-like fixtures, and you have clear bandwidth and latency targets that can be verified on the assembled system.
  • Poor fit when test access is too limited to verify the key measurement metrics, because integration risk stays high when key margins cannot be measured.