VCS80

VCS80

$535.50
  • Description:ISOLATED CURRENT SENSOR
  • Series:VCS
  • Mfr:Vektrex
  • Package:Box

SKU:c75e8a41c487 Category: Brand:

  
  • Quantity
    • -
    • +
  •    
ChipApex WhatsApp

Consult the customer manager about the wholesale price.

consultation hotline:86-132-6715-2157

email:chipapexlimited@gmail.com
Contact the product manager for consultation. One-stop consultation is available.


Do you want a lower wholesale price? Please send us your inquiry and we will reply immediately.

*
*
*
*
Submitting!
Submission successful!
Submission failed!
Email error!
Phone number error!

Product Detailed Parameters

  • Description:ISOLATED CURRENT SENSOR
  • Series:VCS
  • Mfr:Vektrex
  • Package:Box
  • For Measuring:AC/DC
  • Sensor Type:Hall Effect, Differential
  • Current - Sensing:±80A
  • Number of Channels:1
  • Output:Voltage
  • Sensitivity:-
  • Frequency:DC ~ 650kHz
  • Linearity:±0.25%
  • Accuracy:±0.2%
  • Voltage - Supply:9V ~ 18V
  • Response Time:500ns
  • Current - Supply (Max):-
  • Operating Temperature:20°C ~ 50°C
  • Grade:-
  • Qualification:-
  • Polarization:Bidirectional
  • Mounting Type:Panel Mount
  • Package / Case:Module
  • Supplier Device Package:-

Download product information

VCS80

Buying Guide
Summary

Vektrex VCS80 is selected in Current Sensors category when calibration, drift, and environment constraints must be validated early. Key specs include Description (ISOLATED CURRENT SENSOR), Temperature (20°C ~ 50°C), Package/case (Module), and Mounting (Panel Mount).

Selection Notes
  • For VCS80, double-check the mounting type (Panel Mount) for your intended installation method.
  • Confirm the supply current (±80A) is acceptable for standby and active operation.
  • Verify the output type (Voltage) and any logic-level requirements in your design.
  • Verify the operating temperature range (20°C ~ 50°C) and derate as needed in your application.
Alternates & Substitutions
  • For Current Sensors, compare the datasheet test conditions behind key specs and re-check the margins that were tightest during bring-up.
  • When evaluating alternates, treat package/case Module, mounting Panel Mount, packaging Box as non-negotiable unless you are re-spinning the PCB.
  • When in doubt, treat the swap as an ECO: define acceptance criteria, then validate under worst-case operating corners.
  • If you want us to shortlist alternates, share your non-negotiables (package Module, supply 9V ~ 18V, frequency DC ~ 650kHz) plus quantity and target delivery date.
FAQ

Who is the manufacturer of VCS80?
Vektrex

How do I validate sensor performance for VCS80?
Test with real fixtures and environmental conditions, then confirm calibration, drift, and noise behavior meet your requirements.

Which Linearity is specified for VCS80?
±0.25%

Which packaging option is listed for VCS80?
Box

Application Scenarios

In many Current Sensors builds, Vektrex VCS80 is reviewed for predictable behavior, supportability, and stable qualification evidence. Integration often involves placement strategy, airflow considerations, and calibration workflows tied to the target environment. Reliable environmental sensing enables better automation decisions and reduces operational risk. In data centers, distributed sensing typically improves hot-spot detection in constrained airflow channels between racks. Within safety and air-quality monitoring, gas and smoke sensing is qualified for drift and contamination because false alarms and misses are costly. Across indoor safety systems, gas and smoke sensing is validated for response time and long-term drift under variable airflow. Environmental sensing focuses on drift, response time, contamination exposure, and compensation so readings remain meaningful over life. The result is a system that is easier to qualify and less sensitive to small process and layout differences.

Compatibility Advice
  • In practice, check long-term drift and recalibration needs so field performance does not depend on early-life conditions with the final enclosure and cabling.
  • Before committing to volume builds, confirm calibration and drift behavior can be measured and repeated in production rather than inferred from typical curves. This keeps integration from depending on typical-only conditions.
Project Fit
  • Less ideal when integrating Vektrex VCS80 for Current Sensors, noise and interference sources are unknown, so the error budget cannot be bounded, because the integration depends on constraints that cannot be controlled across builds.
VCS80VCS80
$535.50
Buy Now