20311009106

20311009106

  • Description:CURRENT SENSOR
  • Series:-
  • Mfr:HARTING
  • Package:Bulk

SKU:004ff9400cfe Category: Brand:

ChipApex WhatsApp

Consult the customer manager about the wholesale price.

consultation hotline:86-132-6715-2157

email:chipapexlimited@gmail.com
Contact the product manager for consultation. One-stop consultation is available.


Do you want a lower wholesale price? Please send us your inquiry and we will reply immediately.

*
*
*
*
Submitting!
Submission successful!
Submission failed!
Email error!
Phone number error!

Product Detailed Parameters

  • Description:CURRENT SENSOR
  • Series:-
  • Mfr:HARTING
  • Package:Bulk
  • For Measuring:AC/DC
  • Sensor Type:Hall Effect, Closed Loop
  • Current - Sensing:1000A
  • Number of Channels:1
  • Output:-
  • Sensitivity:-
  • Frequency:0Hz ~ 100kHz
  • Linearity:±0.1%
  • Accuracy:±0.4%
  • Voltage - Supply:15V ~ 24V
  • Response Time:1µs
  • Current - Supply (Max):228mA
  • Operating Temperature:-40°C ~ 85°C
  • Grade:-
  • Qualification:-
  • Polarization:-
  • Mounting Type:Panel Mount
  • Package / Case:Module, Single Pass Through
  • Supplier Device Package:-

Download product information

20311009106

Buying Guide
Summary

HARTING 20311009106 is used in Current Sensors category where placement, interface fit, and operating envelope drive measurement reliability. Key specs include Description (CURRENT SENSOR), Temperature (-40°C ~ 85°C), Package/case (Module, Single Pass Through), and Mounting (Panel Mount).

Selection Notes
  • For 20311009106, confirm the operating temperature range (-40°C ~ 85°C) meets your deployment conditions.
  • Verify Sensor Type (Hall Effect, Closed Loop) and compare it against your reference design limits.
  • Confirm the mounting type (Panel Mount) matches your assembly process and reliability requirements.
Alternates & Substitutions
  • For Current Sensors, treat alternates as an integration task and validate the assumptions that matter on the assembled system.
  • Before looking at performance tables, lock package/case Module, Single Pass Through, mounting Panel Mount, packaging Bulk and verify the system envelope (supply 15V ~ 24V, temperature -40°C ~ 85°C) to avoid a non-drop-in swap.
  • Confirm compliance/qualification needs (for example RoHS/REACH or grade) before approving a second source for production.
  • Compare not just numbers but also the conditions: rails, loads, timing, and temperature points behind the spec table.
FAQ

Who is the manufacturer of 20311009106?
HARTING

How do I validate sensor performance for 20311009106?
Test with real fixtures and environmental conditions, then confirm calibration, drift, and noise behavior meet your requirements.

What is the For Measuring of 20311009106?
AC/DC

Which operating temperature range is listed for 20311009106?
-40°C ~ 85°C

Application Scenarios

Selecting HARTING 20311009106 for Current Sensors usually comes down to meeting the system constraints that matter most: limits, interfaces, and testability in the real build. Environmental sensing focuses on drift, response time, contamination exposure, and compensation so readings remain meaningful over life. Designers typically evaluate response time, drift, contamination resistance, and compensation so readings stay meaningful over time. Integration often involves placement strategy, airflow considerations, and calibration workflows tied to the target environment. Across data centers, distributed sensing improves hot-spot detection in constrained airflow channels between racks. Across safety systems, gas and smoke sensing provides early warning in environments with intermittent ventilation. In real deployments, across safety and air-quality monitoring, gas and smoke sensing is qualified for drift and contamination because false alarms and misses are costly. By keeping assumptions testable, teams can iterate faster without accumulating hidden technical debt.

Compatibility Advice
  • In practice, check filtering and bandwidth choices so noise, latency, and stability align with the real control loop or measurement method across temperature and supply corners.
Project Fit
  • Best fit for Current Sensors when you can validate calibration, drift, filtering, and noise under the real environment and cabling.
2031100910620311009106

Click on the inquiry