VTX-214-060-224

VTX-214-060-224

$24.19
  • Description:AC/DC CONVERTER 24V 60W
  • Series:VTX-214
  • Mfr:Vigortronix
  • Package:Bulk

SKU:0e4946fa158b Category: Brand:

  
  • Quantity
    • -
    • +
  •    
ChipApex WhatsApp

Consult the customer manager about the wholesale price.

consultation hotline:86-132-6715-2157

email:chipapexlimited@gmail.com
Contact the product manager for consultation. One-stop consultation is available.


Do you want a lower wholesale price? Please send us your inquiry and we will reply immediately.

*
*
*
*
Submitting!
Submission successful!
Submission failed!
Email error!
Phone number error!

Product Detailed Parameters

  • Description:AC/DC CONVERTER 24V 60W
  • Series:VTX-214
  • Mfr:Vigortronix
  • Package:Bulk
  • Type:Enclosed
  • Number of Outputs:1
  • Voltage - Input:85 - 264 VAC, 100 ~ 370 VDC
  • Voltage - Output 1:24V
  • Voltage - Output 2:-
  • Voltage - Output 3:-
  • Voltage - Output 4:-
  • Current - Output (Max):2.5A
  • Applications:Household Appliances, ITE (Commercial)
  • Features:-
  • Operating Temperature:-40°C ~ 70°C (With Derating)
  • Efficiency:84%
  • Mounting Type:Through Hole
  • Package / Case:4-DIP Module
  • Size / Dimension:3.43" L x 2.05" W x 1.16" H (87.0mm x 52.0mm x 29.5mm)
  • Approval Agency:EN, IEC, UL
  • Standard Number:62368-1; 61558-2; 61000
  • Power (Watts):60 W

Download product information

VTX-214-060-224

Buying Guide
Summary

Vigortronix VTX-214-060-224 is selected in AC DC Converters category when protection behavior and transient response must be validated under realistic load steps. Key specs include Description (AC/DC CONVERTER 24V 60W), Temperature (-40°C ~ 70°C (With Derating)), Package/case (4-DIP Module), Mounting (Through Hole), and Packaging (Bulk).

Selection Notes
  • For VTX-214-060-224, verify the operating temperature range (-40°C ~ 70°C (With Derating)) and derate as needed in your application.
  • Verify Standard Number (62368-1; 61558-2; 61000) and compare it against your reference design limits.
  • Double-check the mounting type (Through Hole) for your intended installation method.
Alternates & Substitutions
  • For AC DC Converters, compare the datasheet test conditions behind key specs and re-check the margins that were tightest during bring-up.
  • If the alternate is “close but not identical”, document the differences and define a measurable acceptance test for production.
  • Check that temperature -40°C ~ 70°C (With Derating) matches your system, then validate at corners instead of relying on typical values.
  • For regulators/converters, match input range 85 - 264 VAC, 100 ~ 370 VDC and validate startup, protection behavior, and thermal headroom under transients.
FAQ

What details help you quote VTX-214-060-224 quickly?
Send the part number (VTX-214-060-224), quantity, target delivery date, and any required packaging or documentation.

What operating temperature range does VTX-214-060-224 support?
-40°C ~ 70°C (With Derating)

Which supply current is specified for VTX-214-060-224?
2.5A

What Voltage - Input is listed for VTX-214-060-224?
85 - 264 VAC, 100 ~ 370 VDC

Application Scenarios

Within production AC DC Converters builds, parts like Vigortronix VTX-214-060-224 are shortlisted for predictable behavior, clear documentation, and stable supply. In many systems, stable rails are what keep converters, RF blocks, and processors inside their performance envelope under real loads. Good supervision and sequencing reduce integration surprises by turning brownouts and hot-plug events into testable behaviors. Within outdoor equipment, derating and surge resilience are treated as primary requirements due to long cables and harsh supplies. Within edge servers and communications modules, multi-rail sequencing and telemetry protect compute and memory during rapid load steps. Within battery-powered tools and portable medical devices, efficiency and low quiescent current extend runtime while keeping transient behavior predictable. At scale, the winner is often the option that is easiest to qualify and least sensitive to small layout and process differences. This approach helps keep sourcing changes safer because the design is anchored to testable criteria.

Compatibility Advice
  • To reduce integration risk, validate the design with the real output capacitors and layout, because stability and EMI are board-dependent. This keeps acceptance criteria measurable and repeatable.
  • Across temperature and supply corners, check thermal headroom in the final enclosure so efficiency and protection behavior remain predictable over temperature. This keeps acceptance criteria measurable and repeatable.
Project Fit
  • Strongest fit when you can verify Vigortronix VTX-214-060-224 for AC DC Converters integration in the final enclosure, when you need predictable rails under load steps and can validate stability, EMI, and thermal rise in the final layout.
  • A practical check is to define acceptance criteria and validate the key assumptions in the final enclosure before approving substitutions.
VTX-214-060-224VTX-214-060-224
$24.19
Buy Now