2AA12-N4-25PPM-M-E

2AA12-N4-25PPM-M-E

$670.44
  • Description:DC/DC CONVERTER
  • Series:UltraVolt® AA
  • Mfr:ULTRAVOLT / Advanced Energy
  • Package:Bulk

SKU:c0e4f4766fa5 Category: Brand:

  
  • Quantity
    • -
    • +
  •    
ChipApex WhatsApp

Consult the customer manager about the wholesale price.

consultation hotline:86-132-6715-2157

email:chipapexlimited@gmail.com
Contact the product manager for consultation. One-stop consultation is available.


Do you want a lower wholesale price? Please send us your inquiry and we will reply immediately.

*
*
*
*
Submitting!
Submission successful!
Submission failed!
Email error!
Phone number error!

Product Detailed Parameters

  • Description:DC/DC CONVERTER
  • Series:UltraVolt® AA
  • Mfr:ULTRAVOLT / Advanced Energy
  • Package:Bulk
  • Type:High Voltage - Non-Isolated Module
  • Number of Outputs:1
  • Voltage - Input (Min):11V
  • Voltage - Input (Max):16V
  • Voltage - Output 1:0 ~ 2000V
  • Voltage - Output 2:-
  • Voltage - Output 3:-
  • Voltage - Output 4:-
  • Current - Output (Max):2mA
  • Power (Watts):4 W
  • Applications:ITE (Commercial)
  • Features:Adjustable Output, Remote On/Off
  • Operating Temperature:-40°C ~ 65°C
  • Efficiency:-
  • Mounting Type:Through Hole
  • Package / Case:11-DIP Module
  • Size / Dimension:2.97" L x 1.50" W x 0.75" H (75.4mm x 38.1mm x 19.1mm)
  • Supplier Device Package:-
  • Control Features:Enable, Active Low
  • Approval Agency:CE, cURus
  • Standard Number:-
  • Grade:-
  • Qualification:-

Download product information

2AA12-N4-25PPM-M-E

Buying Guide
Summary

ULTRAVOLT / Advanced Energy 2AA12-N4-25PPM-M-E is used in DC DC Converters category in power designs where stability, startup behavior, and thermal headroom need to be measurable. Key specs include Description (DC/DC CONVERTER), Supply (0 ~ 2000V), Temperature (-40°C ~ 65°C), Package/case (11-DIP Module), and Mounting (Through Hole).

Selection Notes
  • For 2AA12-N4-25PPM-M-E, confirm the mounting type (Through Hole) matches your assembly process and reliability requirements.
  • Confirm the supply requirement (0 ~ 2000V) is met during startup, transients, and brownout.
  • Confirm the operating temperature range (-40°C ~ 65°C) meets your deployment conditions.
Alternates & Substitutions
  • In DC DC Converters, confirm that alternates preserve startup states and fault behavior so system behavior does not change quietly.
  • Confirm the physical match (package/case 11-DIP Module, mounting Through Hole, packaging Bulk) and the operating corners (supply 0 ~ 2000V, temperature -40°C ~ 65°C) so the substitution is not a hidden redesign.
  • For power parts, match input/output limits first, then validate stability, protection behavior, and thermals under load steps and transients.
  • Confirm startup states and fault behavior are equivalent so the alternate does not change system behavior during brownouts or resets.
FAQ

What details help you quote 2AA12-N4-25PPM-M-E quickly?
Provide the part number (2AA12-N4-25PPM-M-E), quantity, required lead time, and any packaging or documentation requirements.

Who is the manufacturer of 2AA12-N4-25PPM-M-E?
ULTRAVOLT / Advanced Energy

Which Features is listed for 2AA12-N4-25PPM-M-E?
Adjustable Output, Remote On/Off

Can you confirm the Approval Agency for 2AA12-N4-25PPM-M-E?
CE, cURus

Application Scenarios

Selecting ULTRAVOLT / Advanced Energy 2AA12-N4-25PPM-M-E for DC DC Converters usually comes down to meeting the system constraints that matter most: limits, interfaces, and testability in the real build. When power margins are designed in, downstream signal integrity and timing margins are usually easier to hold in production. They manage conversion, sequencing, and supervision so rails remain stable under load steps, brownouts, and surge conditions. Layout and current loops dominate outcomes, so engineers plan for measurements like switch-node ringing and conducted emissions. Once those checks pass, it becomes straightforward to map the part into the real application scenarios below. In real deployments, the practical lens is always the same: validate it in the system, not in isolation. Across industrial drives, auxiliary supplies must remain stable under inverter noise so control loops and sensing remain predictable.

Compatibility Advice
  • For compatibility, check thermal rise after heat soak in the final enclosure, because efficiency and protection thresholds shift with temperature. This keeps qualification evidence reproducible later.
  • To avoid late surprises, verify loop stability with the actual output capacitors and layout, because compensation and parasitics decide transient behavior before release to production.
  • In practice, check thermal rise after heat soak in the final enclosure, because efficiency and protection thresholds shift with temperature before release to production.
Project Fit
  • Best fit when you can test and document ULTRAVOLT / Advanced Energy 2AA12-N4-25PPM-M-E for DC DC Converters integration in the final enclosure, if you need stable rails and predictable fault behavior under load steps and real supply variation.
2AA12-N4-25PPM-M-E2AA12-N4-25PPM-M-E
$670.44
Buy Now