2A24-P30-M-E

2A24-P30-M-E

$870.15
  • Description:DC/DC CONVERTER
  • Series:UltraVolt® A
  • Mfr:ULTRAVOLT / Advanced Energy
  • Package:Bulk

SKU:5ea955fe9e26 Category: Brand:

  
  • Quantity
    • -
    • +
  •    
ChipApex WhatsApp

Consult the customer manager about the wholesale price.

consultation hotline:86-132-6715-2157

email:chipapexlimited@gmail.com
Contact the product manager for consultation. One-stop consultation is available.


Do you want a lower wholesale price? Please send us your inquiry and we will reply immediately.

*
*
*
*
Submitting!
Submission successful!
Submission failed!
Email error!
Phone number error!

Product Detailed Parameters

  • Description:DC/DC CONVERTER
  • Series:UltraVolt® A
  • Mfr:ULTRAVOLT / Advanced Energy
  • Package:Bulk
  • Type:High Voltage - Non-Isolated Module
  • Number of Outputs:1
  • Voltage - Input (Min):23V
  • Voltage - Input (Max):30V
  • Voltage - Output 1:0 ~ 2000V
  • Voltage - Output 2:-
  • Voltage - Output 3:-
  • Voltage - Output 4:-
  • Current - Output (Max):15mA
  • Power (Watts):30 W
  • Applications:ITE (Commercial)
  • Features:Adjustable Output, Remote On/Off
  • Operating Temperature:-40°C ~ 65°C
  • Efficiency:-
  • Mounting Type:Through Hole
  • Package / Case:Module
  • Size / Dimension:4.75" L x 2.00" W x 1.00" H (120.7mm x 50.8mm x 25.4mm)
  • Supplier Device Package:-
  • Control Features:Enable, Active High
  • Approval Agency:CE, cURus
  • Standard Number:-
  • Grade:-
  • Qualification:-

Download product information

2A24-P30-M-E

Buying Guide
Summary

ULTRAVOLT / Advanced Energy 2A24-P30-M-E is used in DC DC Converters category in power designs where stability, startup behavior, and thermal headroom need to be measurable. Key specs include Description (DC/DC CONVERTER), Supply (0 ~ 2000V), Temperature (-40°C ~ 65°C), Package/case (Module), and Mounting (Through Hole).

Selection Notes
  • For 2A24-P30-M-E, make sure the mounting type (Through Hole) matches how the part will be installed and inspected.
  • Ensure the supply current (15mA) is acceptable for battery life and thermal limits.
  • Confirm the operating temperature range (-40°C ~ 65°C) meets your deployment conditions.
  • Validate Voltage - Input (Min) (23V) under the expected test conditions in your application.
Alternates & Substitutions
  • For DC DC Converters, validate alternates under worst-case corners rather than assuming typical-only conditions represent production builds.
  • Treat package/case Module, mounting Through Hole, packaging Bulk as the first filter, then move on to electrical and performance checks.
  • For regulator alternates, confirm startup sequencing, protections, and thermal performance in your actual layout.
  • If you need a second source, provide (package Module, supply 0 ~ 2000V) and we will suggest options to evaluate under a clear test plan.
FAQ

What details help you quote 2A24-P30-M-E quickly?
Provide the part number (2A24-P30-M-E), quantity, required lead time, and any packaging or documentation requirements.

Who is the manufacturer of 2A24-P30-M-E?
ULTRAVOLT / Advanced Energy

What is the mounting type of 2A24-P30-M-E?
Through Hole

Which packaging format is listed for 2A24-P30-M-E?
Bulk

Application Scenarios

For ULTRAVOLT / Advanced Energy 2A24-P30-M-E used in DC DC Converters designs, the shortlist is often driven by predictable margins and a straightforward validation plan. When power margins are designed in, downstream signal integrity and timing margins are usually easier to hold in production. They manage conversion, sequencing, and supervision so rails remain stable under load steps, brownouts, and surge conditions. Layout and current loops dominate outcomes, so engineers plan for measurements like switch-node ringing and conducted emissions. Within battery-powered products, low standby current and predictable fault handling protect runtime and data integrity. In automotive ECUs, they handle cranking dips and load dumps while meeting EMI requirements and protecting mixed-voltage sensor domains. Within edge servers and communications modules, multi-rail sequencing and telemetry protect compute and memory during rapid load steps. In battery-powered tools and portable medical devices, efficiency and low quiescent current extend runtime while keeping transient behavior predictable.

Compatibility Advice
  • To reduce integration risk, confirm measurement points and test access so ripple and load-step behavior can be verified at the point of load. This keeps acceptance criteria measurable and repeatable.
  • In qualification work, check thermal rise after heat soak in the final enclosure, because efficiency and protection thresholds shift with temperature. This helps field behavior stay predictable across lots.
Project Fit
  • Usually not a good fit when integrating ULTRAVOLT / Advanced Energy 2A24-P30-M-E for DC DC Converters, layout and filtering cannot be allocated enough space to control EMI and stability, because the remaining risk is system-level and cannot be bounded by datasheet checks alone.
  • Works best when you can measure and verify ULTRAVOLT / Advanced Energy 2A24-P30-M-E for DC DC Converters integration with the real wiring and cabling, if you need stable rails and predictable fault behavior under load steps and real supply variation.
2A24-P30-M-E2A24-P30-M-E
$870.15
Buy Now