Circuit Protection

Circuit Protection

Circuit protection refers to the strategies and components used to shield electrical systems from damage caused by abnormal conditions like short circuits, overcurrent, overvoltage, or excessive temperature. A protected circuit is designed to safely disconnect or redirect dangerous electrical energy before it can harm devices, wiring, or users. Without appropriate protection, faults can cause equipment failure, fire hazards, or even electric shocks, especially in sensitive electronic and motor control applications. Two of the most widely used protection devices are fuses and circuit breakers. A fuse contains a metal wire that melts when the current exceeds a specific threshold, permanently breaking the circuit to prevent further damage. Fuses are simple and cost-effective, but must be replaced once blown. Circuit breakers, in contrast, are mechanical switches that detect overcurrent and trip open—disconnecting power without requiring replacement. These can be reset once the fault is cleared. Ground fault circuit interrupters (GFCIs) are a specialized type of breaker used to protect people from electric shock. They monitor current balance between the hot and neutral lines and trip instantly when leakage to ground is detected, often caused by damaged insulation or contact with water. In modern electronic systems, solid-state circuit protection devices are increasingly important. Components such as varistors—especially metal oxide varistors (MOVs)—and transient voltage suppressors (TVS) are designed to handle voltage spikes or transients caused by inductive loads, lightning strikes, or static discharge. These devices can absorb or redirect excess energy, protecting delicate semiconductors from failure. Other devices like thermal cutoffs (thermal fuses) disconnect circuits when operating temperatures rise too high, while gas discharge tubes (GDT) arresters protect against high-energy surges, especially in communication or low-voltage power lines.

Screen Default Ranking Price By Date
Select productsMfrDescriptionPackageSupplier Device PackageMounting TypeSeriesOperating Temperature
0001.2713.11
0001.2713.11
$1.89000
SCHURTER Inc.FUSE CERM 8A 250VAC 150VDC 5X20BulkRequires HolderSMD-SPT-55°C ~ 125°C
0001.2713.22
0001.2713.22
$1.86000
SCHURTER Inc.FUSE CERM 8A 250VAC 150VDC 5X20Tape & Reel (TR),Cut Tape (CT)Requires HolderSMD-SPT-55°C ~ 125°C
0001.2714.11
0001.2714.11
$1.89000
SCHURTER Inc.FUSE CERM 10A 250VAC 150VDC 5X20BulkRequires HolderSMD-SPT-55°C ~ 125°C
0001.2714.22
0001.2714.22
$1.20000
SCHURTER Inc.FUSE CERM 10A 250VAC 150VDC 5X20Tape & Reel (TR),Cut Tape (CT)Requires HolderSMD-SPT-55°C ~ 125°C
0001.2715.11
0001.2715.11
$1.89000
SCHURTER Inc.FUSE CERAMIC 12.5A 250VAC 125VDCBulkRequires HolderSMD-SPT-55°C ~ 125°C
0001.2715.22
0001.2715.22
$1.20000
SCHURTER Inc.FUSE CERAMIC 12.5A 250VAC 125VDCTape & Reel (TR),Cut Tape (CT)Requires HolderSMD-SPT-55°C ~ 125°C
0001.2716.11
0001.2716.11
$2.05000
SCHURTER Inc.FUSE CERM 16A 250VAC 125VDC 5X20BulkRequires HolderSMD-SPT-55°C ~ 125°C
0001.2716.22
0001.2716.22
$1.32000
SCHURTER Inc.FUSE CERM 16A 250VAC 125VDC 5X20Tape & Reel (TR),Cut Tape (CT)Requires HolderSMD-SPT-55°C ~ 125°C
Add ComparisonUp to 4 can be added