Isolators

Isolators

Isolators are components used to transmit signals across two sections of a circuit that must remain electrically separated for safety, noise immunity, or functional reasons. This electrical separation—called galvanic isolation—prevents current flow while still allowing data or control signals to pass through. Isolators are especially important in high-voltage or noisy environments, such as industrial automation, motor control systems, or medical electronics. Isolators are signal-level devices that facilitate safe communication between subsystems without direct electrical contact. There are two primary types of isolators: optical isolators (also known as optocouplers) and digital isolators. Optical isolators use light to transmit information across an isolation barrier. A typical optocoupler consists of an LED on the input side and a phototransistor, photodiode, SCR, or Triac on the output side. When current flows through the LED, it emits light that activates the output component, allowing the signal to be reproduced on the isolated side. Optocouplers are widely used in applications requiring moderate speed and high-voltage isolation—such as microcontroller interfaces, SMPS (switch mode power supply) feedback loops, or PLC input modules. They are favored for their simplicity and excellent electrical noise immunity. Digital isolators, on the other hand, do not rely on light. Instead, they typically use capacitive or magnetic coupling to transmit digital signals across the isolation barrier. These isolators offer several advantages over optocouplers, including higher data rates, lower power consumption, better temperature stability, and longer lifespan since they avoid LED aging. Digital isolators are particularly well-suited for high-speed communication interfaces like SPI, I²C, or UART, where timing and signal integrity are critical. However, they may be more sensitive to certain types of transient interference, depending on the design and application. Choosing between an optical and a digital isolator depends on several factors: signal type (analog or digital), speed, voltage isolation requirements, environmental conditions, and reliability expectations. For example, optocouplers might still be preferred in high-voltage analog feedback paths due to their robust noise immunity, while digital isolators may be better suited for fast, compact, low-power digital systems.

Screen Default Ranking Price By Date
Select productsMfrDescriptionPackageSupplier Device PackageMounting TypeSeriesOperating Temperature
IS604G
IS604G
$0.78000
Isocom Components 2004 LTDOPTOISO 5.3KV TRANS W/BASE 6-DIPTube6-DIPThrough HoleIS604-55°C ~ 100°C
IS604SM
IS604SM
$0.78000
Isocom Components 2004 LTDOPTOISO 5.3KV 1CH TRANS W/BASETube-Surface MountIS604-55°C ~ 100°C
IS604SMT&R
IS604SMT&R
$0.30000
Isocom Components 2004 LTDOPTOISO 5.3KV 1CH TRANS W/BASETape & Reel (TR)-Surface MountIS604-55°C ~ 100°C
IS604X
IS604X
$0.60000
Isocom Components 2004 LTDOPTOISO 5.3KV TRANS W/BASE 6-DIPTube6-DIPThrough HoleIS604-55°C ~ 100°C
IS604XG
IS604XG
$0.78000
Isocom Components 2004 LTDOPTOISO 5.3KV TRANS W/BASE 6-DIPTube6-DIPThrough HoleIS604-55°C ~ 100°C
IS604XSM
IS604XSM
$0.78000
Isocom Components 2004 LTDOPTOISO 5.3KV 1CH TRANS W/BASETube-Surface MountIS604-55°C ~ 100°C
IS604XSMT&R
IS604XSMT&R
$0.30000
Isocom Components 2004 LTDOPTOISO 5.3KV 1CH TRANS W/BASETape & Reel (TR)-Surface MountIS604-55°C ~ 100°C
IS607
IS607
$0.71000
Isocom Components 2004 LTDOPTOISOLTR 5.3KV TRIAC 1CH 6-DIPTube6-DIPThrough HoleIS607-40°C ~ 100°C
Add ComparisonUp to 4 can be added