0.3 PSI-G-PRIME-MINI

0.3 PSI-G-PRIME-MINI

$103.50
  • Description:SENSOR 0.3PSIG .02V
  • Series:ACPC
  • Mfr:Amphenol All Sensors Corporation
  • Package:Tube

SKU:31d15e010031 Category: Brand:

  
  • Quantity
    • -
    • +
  •    
ChipApex WhatsApp

Consult the customer manager about the wholesale price.

consultation hotline:86-132-6715-2157

email:chipapexlimited@gmail.com
Contact the product manager for consultation. One-stop consultation is available.


Do you want a lower wholesale price? Please send us your inquiry and we will reply immediately.

*
*
*
*
Submitting!
Submission successful!
Submission failed!
Email error!
Phone number error!

Product Detailed Parameters

  • Description:SENSOR 0.3PSIG .02V
  • Series:ACPC
  • Mfr:Amphenol All Sensors Corporation
  • Package:Tube
  • Applications:Board Mount
  • Pressure Type:Vented Gauge
  • Operating Pressure:0.3PSI (2.07kPa)
  • Output Type:Wheatstone Bridge
  • Output:0 mV ~ 20 mV (12V)
  • Accuracy:±0.25%
  • Voltage - Supply:16V
  • Port Size:-
  • Port Style:No Port
  • Features:Temperature Compensated
  • Termination Style:PC Pin
  • Maximum Pressure:3PSI (20.68kPa)
  • Operating Temperature:-25°C ~ 85°C
  • Mounting Type:Through Hole
  • Package / Case:4-SIP Module
  • Supplier Device Package:-
  • Grade:-
  • Qualification:-

Download product information

0.3 PSI-G-PRIME-MINI

Buying Guide
Summary

Amphenol All Sensors Corporation 0-3-PSI-G-PRIME-MINI is used in Pressure Sensors, Transducers category where placement, interface fit, and operating envelope drive measurement reliability. Key specs include Description (SENSOR 0.3PSIG .02V), Output type (Wheatstone Bridge), Temperature (-25°C ~ 85°C), Package/case (4-SIP Module), and Mounting (Through Hole).

Selection Notes
  • For 0-3-PSI-G-PRIME-MINI, ensure the output type (Wheatstone Bridge) is compatible with the downstream interface.
  • Confirm the operating temperature range (-25°C ~ 85°C) meets your deployment conditions.
  • Double-check Accuracy (±0.25%) against your specification and operating conditions.
  • Make sure the mounting type (Through Hole) matches how the part will be installed and inspected.
Alternates & Substitutions
  • For Pressure Sensors, Transducers, compare the datasheet test conditions behind key specs and re-check the margins that were tightest during bring-up.
  • Check that supply 16V, temperature -25°C ~ 85°C matches your system, then validate at corners instead of relying on typical values.
  • Lock the mechanical constraints first (package/case 4-SIP Module, mounting Through Hole, packaging Tube) before comparing performance specs.
  • If you are qualifying a second source, align documentation/traceability requirements early to avoid surprises in procurement.
FAQ

How do I validate sensor performance for 0-3-PSI-G-PRIME-MINI?
Test with real fixtures and environmental conditions, then confirm calibration, drift, and noise behavior meet your requirements.

What is the output type of 0-3-PSI-G-PRIME-MINI?
Wheatstone Bridge

What is the Port Style of 0-3-PSI-G-PRIME-MINI?
No Port

Which Output is specified for 0-3-PSI-G-PRIME-MINI?
0 mV ~ 20 mV (12V)

Application Scenarios

Amphenol All Sensors Corporation 0-3-PSI-G-PRIME-MINI is listed under the Pressure Sensors, Transducers category and is commonly used when correctness, reliability, and qualification repeatability matter. Pressure sensing emphasizes porting, response time, drift, and compensation so accuracy remains stable under real mechanical and thermal stress. They monitor conditions such as temperature, humidity, light, gas concentration, or particulates for safety and efficiency. Designers often evaluate response time, drift, contamination resistance, and compensation so readings stay meaningful over time. Across consumer devices, compact sensing enables adaptive control under tight power budgets. In industrial safety, gas and smoke sensing is treated as a reliability problem, so calibration and drift behavior are validated over time. Within smart buildings, environmental sensors drive HVAC optimization in ceiling nodes exposed to dust and changing airflow patterns.

Compatibility Advice
  • To keep validation repeatable, validate noise and latency with production-like cabling so the system behaves the same outside the lab. This keeps acceptance criteria measurable and repeatable.
  • In practice, check filtering and bandwidth choices so noise and latency align with the control or monitoring use-case during bring-up and production test.
  • In practice, validate noise and latency with production-like cabling so the system behaves the same outside the lab before committing to volume builds.
Project Fit
  • Usually not a good fit when integrating Amphenol All Sensors Corporation 0-3-PSI-G-PRIME-MINI for Pressure Sensors, Transducers, calibration and compensation cannot be supported but long-term accuracy is still expected, because validation would rely on assumptions that cannot be re-tested later.