1-1393219-2

1-1393219-2

  • Description:RELAY GEN PURPOSE SPDT 5A 36V
  • Series:PE, SCHRACK
  • Mfr:TE Connectivity Potter & Brumfield Relays
  • Package:Bulk

SKU:e4a7f9fbfb79 Category: Brand:

ChipApex WhatsApp

Consult the customer manager about the wholesale price.

consultation hotline:86-132-6715-2157

email:chipapexlimited@gmail.com
Contact the product manager for consultation. One-stop consultation is available.


Do you want a lower wholesale price? Please send us your inquiry and we will reply immediately.

*
*
*
*
Submitting!
Submission successful!
Submission failed!
Email error!
Phone number error!

Product Detailed Parameters

  • Description:RELAY GEN PURPOSE SPDT 5A 36V
  • Series:PE, SCHRACK
  • Mfr:TE Connectivity Potter & Brumfield Relays
  • Package:Bulk
  • Mounting Type:Through Hole
  • Coil Voltage:36VDC
  • Contact Form:SPDT (1 Form C)
  • Contact Rating (Current):5:00 AM
  • Switching Voltage:400VAC - Max
  • Load - Max Switching:2000VA
  • Coil Current:5.8 mA
  • Coil Type:Non Latching
  • Features:-
  • Termination Style:PC Pin
  • Seal Rating:Sealed - Flux Protection
  • Coil Insulation:-
  • Must Operate Voltage:27 VDC
  • Must Release Voltage:3.6 VDC
  • Operating Temperature:-40°C ~ 85°C
  • Contact Material:Silver Nickel (AgNi)
  • Approval Agency:cURus, VDE
  • Relay Type:General Purpose
  • Grade:-
  • Qualification:-
  • Operate Time:8 ms
  • Release Time:8 ms

Download product information

1-1393219-2

Buying Guide
Summary

TE Connectivity Potter & Brumfield Relays 1-1393219-2 is used in Power Relays, Over 2 Amps category when predictable switching behavior and derating under real loads are required. Key specs include Description (RELAY GEN PURPOSE SPDT 5A 36V), Temperature (-40°C ~ 85°C), Mounting (Through Hole), and Packaging (Bulk).

Selection Notes
  • For 1-1393219-2, confirm the operating temperature range (-40°C ~ 85°C) meets your deployment conditions.
  • Verify Switching Voltage (400VAC - Max) and compare it against your reference design limits.
  • Verify the mounting type (Through Hole) fits your manufacturing and inspection workflow.
  • Verify the coil voltage (36VDC) matches your drive circuit and allows for dropout margins.
Alternates & Substitutions
  • For Power Relays, Over 2 Amps, treat alternates as an integration task and validate the assumptions that matter on the assembled system.
  • Confirm startup states and fault behavior are equivalent so the alternate does not change system behavior during brownouts or resets.
  • Start with mechanical equivalence and keep mounting Through Hole, packaging Bulk aligned so the alternate is footprint-safe.
  • For relays/switches, match contact form SPDT (1 Form C), coil 36VDC, contact rating 5:00 AM and derate for inductive loads and inrush current.
FAQ

What is the Contact Rating (Current) of 1-1393219-2?
5:00 AM

Which Operate Time is listed for 1-1393219-2?
8 ms

What current consumption is specified for 1-1393219-2?
5.8 mA

Which Approval Agency is listed for 1-1393219-2?
cURus, VDE

Application Scenarios

Selecting TE Connectivity Potter & Brumfield Relays 1-1393219-2 for Power Relays, Over 2 Amps usually comes down to meeting the system constraints that matter most: limits, interfaces, and testability in the real build. In real deployments, they provide controlled switching for signals and power, enabling isolation, routing, and safe user interaction. Designers typically balance lifetime, inrush behavior, leakage, and environmental sealing depending on load type and duty cycle. In industrial safety, switching is chosen for predictable behavior and validated failure modes under contamination and vibration. In emergency-stop chains, deterministic switching behavior supports safe state transitions under bounce and contamination. In heavy machinery, switching is validated for inductive kickback and contact wear during repetitive actuator cycles. From a lifecycle perspective, clear selection criteria and repeatable validation practices make long-term support simpler.

Compatibility Advice
  • For second-source planning, confirm contact materials match the load profile so aging and corrosion remain predictable over life during bring-up and production test.
  • In board-level integration, confirm mounting and sealing align with the environment, because ingress often drives intermittent failures before committing to volume builds.
  • For Power Relays, Over 2 Amps, on the assembled PCB, confirm mounting and sealing align with the environment, because ingress often drives intermittent failures. This keeps integration from depending on typical-only conditions.
Project Fit
  • A strong fit when you can validate TE Connectivity Potter & Brumfield Relays 1-1393219-2 for Power Relays, Over 2 Amps integration across temperature and supply corners, and you can control contamination and ingress with sealing and placement.
  • More fragile when integrating TE Connectivity Potter & Brumfield Relays 1-1393219-2 for Power Relays, Over 2 Amps, inductive transients are unbounded and protection is not coordinated, because the integration depends on constraints that cannot be controlled across builds.
1-1393219-21-1393219-2

Click on the inquiry