10ACEW_03S4

10ACEW_03S4

$8.03
  • Description:ENCLOSED AC DC CONVERTERS 1 OUTP
  • Series:10ACEW_4 (10W)
  • Mfr:GAPTEC Electronic
  • Package:Retail Package

SKU:d939eb8b13be Category: Brand:

  
  • Quantity
    • -
    • +
  •    
ChipApex WhatsApp

Consult the customer manager about the wholesale price.

consultation hotline:86-132-6715-2157

email:chipapexlimited@gmail.com
Contact the product manager for consultation. One-stop consultation is available.


Do you want a lower wholesale price? Please send us your inquiry and we will reply immediately.

*
*
*
*
Submitting!
Submission successful!
Submission failed!
Email error!
Phone number error!

Product Detailed Parameters

  • Description:ENCLOSED AC DC CONVERTERS 1 OUTP
  • Series:10ACEW_4 (10W)
  • Mfr:GAPTEC Electronic
  • Package:Retail Package
  • Type:Enclosed
  • Number of Outputs:1
  • Voltage - Input:85 ~ 305 VAC, 100 ~ 430 VDC
  • Voltage - Output 1:3.3V
  • Voltage - Output 2:-
  • Voltage - Output 3:-
  • Voltage - Output 4:-
  • Current - Output (Max):2.6A
  • Applications:Household Appliances, ITE (Commercial)
  • Features:-
  • Operating Temperature:-40°C ~ 85°C (With Derating)
  • Efficiency:74%
  • Mounting Type:Through Hole
  • Package / Case:6-DIP Module, 4 Leads
  • Size / Dimension:1.57" L x 1.00" W x 0.83" H (40.0mm x 25.4mm x 21.0mm)
  • Approval Agency:cURus, UL
  • Standard Number:60335-1; 62368-1
  • Power (Watts):8.58 W

Download product information

10ACEW_03S4

Buying Guide
Summary

GAPTEC Electronic 10ACEW_03S4 is selected in AC DC Converters category when protection behavior and transient response must be validated under realistic load steps. Key specs include Description (ENCLOSED AC DC CONVERTERS 1 OUTP), Temperature (-40°C ~ 85°C (With Derating)), Package/case (6-DIP Module, 4 Leads), Mounting (Through Hole), and Packaging (Retail Package).

Selection Notes
  • For 10ACEW_03S4, check the efficiency (74%) under your specific load conditions to estimate thermal dissipation.
  • Confirm Approval Agency (cURus, UL) is suitable for your use case and operating conditions.
  • Ensure the package/case (6-DIP Module, 4 Leads) and land pattern match your PCB layout before procurement.
  • Check the supply current (2.6A) in your power budget and thermal plan.
Alternates & Substitutions
  • For AC DC Converters, treat alternates as an integration task and validate the assumptions that matter on the assembled system.
  • Make sure the alternate stays inside your system envelope: temperature -40°C ~ 85°C (With Derating).
  • Keep the assembly and footprint constraints consistent (package/case 6-DIP Module, 4 Leads, mounting Through Hole, packaging Retail Package) to avoid a late PCB change.
  • For power substitutions, align input range 85 ~ 305 VAC, 100 ~ 430 VDC and re-check compensation/layout guidance because stability and thermals are often alternate-specific.
FAQ

Who is the manufacturer of 10ACEW_03S4?
GAPTEC Electronic

Any tips for derating and validation for 10ACEW_03S4?
Validate at worst-case temperature and load, confirm thermal headroom, and check protection and startup behavior with margin.

What is the Efficiency of 10ACEW_03S4?
74%

Can you confirm the Voltage - Input for 10ACEW_03S4?
85 ~ 305 VAC, 100 ~ 430 VDC

Application Scenarios

In practice, selecting GAPTEC Electronic 10ACEW_03S4 for AC DC Converters usually comes down to meeting the system constraints that matter most: limits, interfaces, and testability in the real build. Power-stage choices tend to pay back in validation time by making EMI, thermal headroom, and protection behavior easier to prove. In many systems, stable rails are what keep converters, RF blocks, and processors inside their performance envelope under real loads. In portable instrumentation, clean rails and predictable drift keep measurements repeatable across temperature and time. In practice, within edge compute nodes, thermal headroom and EMI behavior often dominate board-level integration risk in compact airflow paths. In automotive body electronics, converters must be robust to harness noise and intermittent load changes without injecting audible or RF interference. In field deployments, stable behavior across temperature and supply variation is what prevents hard-to-reproduce failures.

Compatibility Advice
  • Validate the design with the real output capacitors and layout, because stability and EMI are board-dependent before release to production.
  • Across temperature and supply corners, confirm the converter matches input transients and sequencing needs, including startup, brownout, and fault behavior. This keeps qualification evidence reproducible later.
Project Fit
  • A strong fit when you can verify GAPTEC Electronic 10ACEW_03S4 for AC DC Converters integration in the final enclosure, typically when you can verify sequencing and fault recovery behavior on the assembled system.
  • Less ideal when integrating GAPTEC Electronic 10ACEW_03S4 for AC DC Converters, thermal headroom is too tight to keep margins stable after heat soak, because the integration depends on constraints that cannot be controlled across builds.
10ACEW_03S410ACEW_03S4
$8.03
Buy Now