10ACEW_09S4A

10ACEW_09S4A

$7.22
  • Description:ENCLOSED AC DC CONVERTERS 1 OUTP
  • Series:10ACEW_4A (10W)
  • Mfr:GAPTEC Electronic
  • Package:Retail Package

SKU:254548596c2a Category: Brand:

  
  • Quantity
    • -
    • +
  •    
ChipApex WhatsApp

Consult the customer manager about the wholesale price.

consultation hotline:86-132-6715-2157

email:chipapexlimited@gmail.com
Contact the product manager for consultation. One-stop consultation is available.


Do you want a lower wholesale price? Please send us your inquiry and we will reply immediately.

*
*
*
*
Submitting!
Submission successful!
Submission failed!
Email error!
Phone number error!

Product Detailed Parameters

  • Description:ENCLOSED AC DC CONVERTERS 1 OUTP
  • Series:10ACEW_4A (10W)
  • Mfr:GAPTEC Electronic
  • Package:Retail Package
  • Type:Enclosed
  • Number of Outputs:1
  • Voltage - Input:85 ~ 305 VAC, 100 ~ 430 VDC
  • Voltage - Output 1:9V
  • Voltage - Output 2:-
  • Voltage - Output 3:-
  • Voltage - Output 4:-
  • Current - Output (Max):1.1A
  • Applications:Household Appliances, ITE (Commercial)
  • Features:Universal Input
  • Operating Temperature:-40°C ~ 85°C (With Derating)
  • Efficiency:84%
  • Mounting Type:Through Hole
  • Package / Case:5-DIP Module, 4 Leads
  • Size / Dimension:1.87" L x 1.06" W x 0.93" H (47.6mm x 26.8mm x 23.5mm)
  • Approval Agency:CE, cURus, UL
  • Standard Number:60335-1; 62368-1
  • Power (Watts):10 W

Download product information

10ACEW_09S4A

Buying Guide
Summary

GAPTEC Electronic 10ACEW_09S4A is selected in AC DC Converters category when protection behavior and transient response must be validated under realistic load steps. Key specs include Description (ENCLOSED AC DC CONVERTERS 1 OUTP), Temperature (-40°C ~ 85°C (With Derating)), Package/case (5-DIP Module, 4 Leads), Mounting (Through Hole), and Packaging (Retail Package).

Selection Notes
  • For 10ACEW_09S4A, check the supply current (1.1A) in your power budget and thermal plan.
  • Check the efficiency (84%) under your specific load conditions to estimate thermal dissipation.
  • Make sure Features (Universal Input) aligns with your design targets and verification plan.
  • Ensure the package/case (5-DIP Module, 4 Leads) and land pattern match your PCB layout before procurement.
Alternates & Substitutions
  • In AC DC Converters, confirm that alternates preserve startup states and fault behavior so system behavior does not change quietly.
  • For substitutions, match the footprint-related items first: package/case 5-DIP Module, 4 Leads, mounting Through Hole, packaging Retail Package.
  • For power substitutions, align input range 85 ~ 305 VAC, 100 ~ 430 VDC and re-check compensation/layout guidance because stability and thermals are often alternate-specific.
  • If substitutions are likely, write down the non-negotiables and re-check them when the supply chain changes, not after field failures.
FAQ

What details help you quote 10ACEW_09S4A quickly?
Send the part number (10ACEW_09S4A), quantity, target delivery date, and any required packaging or documentation.

What Size / Dimension is listed for 10ACEW_09S4A?
1.87" L x 1.06" W x 0.93" H (47.6mm x 26.8mm x 23.5mm)

What is the Standard Number of 10ACEW_09S4A?
60335-1; 62368-1

What is the packaging of 10ACEW_09S4A?
Retail Package

Application Scenarios

Within many AC DC Converters builds, GAPTEC Electronic 10ACEW_09S4A is reviewed for predictable behavior, supportability, and stable qualification evidence. Across many systems, stable rails are what keep converters, RF blocks, and processors inside their performance envelope under real loads. In practice, good supervision and sequencing reduce integration surprises by turning brownouts and hot-plug events into testable behaviors. In outdoor equipment, derating and surge resilience are treated as primary requirements due to long cables and harsh supplies. In medical equipment, power integrity and fault behavior are validated to protect both measurements and safety requirements over long duty cycles. In outdoor IoT enclosures, derating and surge resilience matter because supply quality and temperature drift are less controlled. After that, the focus becomes predictable bring-up and avoiding surprises during compliance and production ramp. This is the kind of discipline that reduces re-spin risk and keeps schedules more predictable.

Compatibility Advice
  • For compatibility, confirm compensation and stability with the chosen capacitor ESR so the loop stays stable across substitutions. This keeps qualification evidence reproducible later.
  • Confirm compensation and stability with the chosen capacitor ESR so the loop stays stable across substitutions on the assembled PCB.
Project Fit
  • Good fit when you can test and document GAPTEC Electronic 10ACEW_09S4A for AC DC Converters integration with the real wiring and cabling, and you must tolerate supply variation and surges in real wiring environments.
  • Poor fit when fault coordination with upstream supplies cannot be validated, because the behavior cannot be verified in a repeatable way.
10ACEW_09S4A10ACEW_09S4A
$7.22
Buy Now