19RL 202

19RL 202

$97.75
  • Description:ANSI CT,2000:5,4.25"ID,24"L,Dnut
  • Series:Omega 30
  • Mfr:Sifam Tinsley Instrumentation Inc
  • Package:Retail Package

SKU:bf25a26af491 Category: Brand:

  
  • Quantity
    • -
    • +
  •    
ChipApex WhatsApp

Consult the customer manager about the wholesale price.

consultation hotline:86-132-6715-2157

email:chipapexlimited@gmail.com
Contact the product manager for consultation. One-stop consultation is available.


Do you want a lower wholesale price? Please send us your inquiry and we will reply immediately.

*
*
*
*
Submitting!
Submission successful!
Submission failed!
Email error!
Phone number error!

Product Detailed Parameters

  • Description:ANSI CT,2000:5,4.25"ID,24"L,Dnut
  • Series:Omega 30
  • Mfr:Sifam Tinsley Instrumentation Inc
  • Package:Retail Package
  • Frequency Range:50Hz ~ 400Hz
  • Type:Non-Invasive (Solid Core)
  • Inductance:-
  • ET (Volt-Time):-
  • Current Ratio:400:01:00
  • DC Resistance (DCR):-
  • Ratings:-
  • Mounting Type:Free Hanging (In-Line)
  • Size / Dimension:5.920" L x 4.250" W (150.36mm x 107.95mm)
  • Height - Seated (Max):1.130" (28.70mm)
  • Termination Style:Wire Leads
  • Turns Ratio - Primary:Secondary:2000:05:00
  • Current Rating (Amps):2000 A

Download product information

19RL 202

Buying Guide
Summary

Sifam Tinsley Instrumentation Inc 19RL-202 is sourced in Current Sense Transformers category when teams want clear constraints and a repeatable validation path. Key specs include Description (ANSI CT, 2000:5, 4.25"ID, etc.), Series (Omega 30), Type (Non-Invasive (Solid Core)), Packaging (Retail Package), and Mounting (Free Hanging (In-Line)).

Selection Notes
  • For 19RL-202, check the supply current (2000 A) in your power budget and thermal plan.
  • Ensure the frequency range (50Hz ~ 400Hz) is compatible with your signal-chain matching and filtering plan.
  • Confirm Size / Dimension (5.920" L x 4.250" W (150.36mm x 107.95mm)) is suitable for your use case and operating conditions.
  • Confirm the mounting type (Free Hanging (In-Line)) is suitable for your production flow and reliability target.
Alternates & Substitutions
  • For Current Sense Transformers, validate alternates under worst-case corners rather than assuming typical-only conditions represent production builds.
  • Lock the mechanical constraints first (mounting Free Hanging (In-Line), packaging Retail Package) before comparing performance specs.
  • If you are qualifying a second source, align documentation/traceability requirements early to avoid surprises in procurement.
  • If you need a second source, provide (frequency 50Hz ~ 400Hz) and we will suggest options to evaluate under a clear test plan.
FAQ

Who is the manufacturer of 19RL-202?
Sifam Tinsley Instrumentation Inc

What should I compare when selecting an alternate for 19RL-202?
Compare footprint/pinout, key electrical limits, temperature range, and interface requirements, then validate under worst-case conditions.

What is the mounting method for 19RL-202?
Free Hanging (In-Line)

Which Height - Seated (Max) is listed for 19RL-202?
1.130" (28.70mm)

Application Scenarios

Sifam Tinsley Instrumentation Inc 19RL-202 is listed under the Current Sense Transformers category and is commonly used when correctness, reliability, and qualification repeatability matter. They often define safety margins and EMC behavior in SMPS, PoE, pulse transmission, and sensing solutions. In real deployments, a properly designed transformer stage improves safety, efficiency, and predictable field performance. In telecom power modules, magnetics and isolation support regulatory compliance and stable operation across multi-board systems. In production, insulation systems and creepage/clearance must match regional safety standards and long-life expectations. Within PoE and Ethernet, magnetics provide isolation and common-mode rejection in electrically noisy facilities.

Compatibility Advice
  • Before freezing the BOM, confirm that substitutions preserve dielectric or core material behavior because that often changes drift and loss more than the nominal value. This keeps integration from depending on typical-only conditions.
  • In practice, confirm tolerance, drift, and temperature coefficients match the accuracy and stability the circuit actually needs with the real source, load, and wiring.
  • Validate derating under voltage and ripple current so passives do not run at the edge in continuous duty on the assembled PCB.
Project Fit
  • Good fit when you can test and document Sifam Tinsley Instrumentation Inc 19RL-202 for Current Sense Transformers integration on the assembled PCB, and you have a defined accuracy budget and can verify drift and tolerance stack-up in production.
  • Poor fit when isolation and mechanical spacing cannot be guaranteed in the final design, increasing compliance risk, because the remaining risk is system-level and cannot be bounded by datasheet checks alone.