200H-3-1-1000/6000-101

200H-3-1-1000/6000-101

$74.25
  • Description:Mechanical Pressure Switch
  • Series:200
  • Mfr:NOSHOK, Inc.
  • Package:Case

SKU:a73bb20e315a Category: Brand:

  
  • Quantity
    • -
    • +
  •    
ChipApex WhatsApp

Consult the customer manager about the wholesale price.

consultation hotline:86-132-6715-2157

email:chipapexlimited@gmail.com
Contact the product manager for consultation. One-stop consultation is available.


Do you want a lower wholesale price? Please send us your inquiry and we will reply immediately.

*
*
*
*
Submitting!
Submission successful!
Submission failed!
Email error!
Phone number error!

Product Detailed Parameters

  • Description:Mechanical Pressure Switch
  • Series:200
  • Mfr:NOSHOK, Inc.
  • Package:Case
  • Applications:Industrial Automation
  • Pressure Type:Switch
  • Operating Pressure:1000PSI ~ 6000PSI (6894.76kPa ~ 41368.54kPa)
  • Output Type:SPDT
  • Output:-
  • Accuracy:-
  • Voltage - Supply:-
  • Port Size:Male - 1/8" (3.18mm) NPT
  • Port Style:Threaded
  • Features:-
  • Termination Style:Deutsch, 3 Pin
  • Maximum Pressure:9000PSI (62052.81kPa)
  • Operating Temperature:-20°C ~ 80°C
  • Mounting Type:-
  • Package / Case:Cylinder, Threaded
  • Supplier Device Package:-
  • Grade:-
  • Qualification:-

Download product information

200H-3-1-1000/6000-101

Buying Guide
Summary

NOSHOK, Inc. 200H-3-1-1000-6000-101 is used in Pressure Sensors, Transducers category where placement, interface fit, and operating envelope drive measurement reliability. Key specs include Description (Mechanical Pressure Switch), Output type (SPDT), Temperature (-20°C ~ 80°C), and Package/case (Cylinder, Threaded).

Selection Notes
  • For 200H-3-1-1000-6000-101, double-check Maximum Pressure (9000PSI (62052.81kPa)) against your specification and operating conditions.
  • Double-check the package/case (Cylinder, Threaded) and recommended land pattern before ordering.
  • Ensure the output type (SPDT) is compatible with the downstream interface.
  • Confirm the operating temperature range (-20°C ~ 80°C) meets your deployment conditions.
Alternates & Substitutions
  • In Pressure Sensors, Transducers designs, define acceptance criteria up front so alternates can be qualified and repeated in production.
  • Confirm startup states and fault behavior are equivalent so the alternate does not change system behavior during brownouts or resets.
  • Confirm the real operating corners (temperature -20°C ~ 80°C) and avoid swaps that only work at typical conditions.
  • Confirm compliance/qualification needs (for example RoHS/REACH or grade) before approving a second source for production.
FAQ

What details help you quote 200H-3-1-1000-6000-101 quickly?
Send the part number (200H-3-1-1000-6000-101), quantity, target delivery date, and any required packaging or documentation.

What Pressure Type does 200H-3-1-1000-6000-101 have?
Switch

What Termination Style is listed for 200H-3-1-1000-6000-101?
Deutsch, 3 Pin

Can you confirm the Port Size for 200H-3-1-1000-6000-101?
Male - 1/8" (3.18mm) NPT

Application Scenarios

In real deployments, across production Pressure Sensors, Transducers builds, parts like NOSHOK, Inc. 200H-3-1-1000-6000-101 are shortlisted for predictable behavior, clear documentation, and stable supply. Reliable environmental sensing enables better automation decisions and reduces operational risk. They monitor conditions such as temperature, humidity, light, gas concentration, or particulates for safety and efficiency. In agriculture, humidity and particulate sensing supports greenhouse automation where condensation is common. Within smart buildings, environmental sensors drive HVAC optimization in ceiling nodes exposed to dust and changing airflow patterns. Within industrial process lines, temperature and gas monitoring protects operators near ovens, tanks, or clean rooms with strict calibration rules. Pressure sensing emphasizes porting, response time, drift, and compensation so accuracy remains stable under real mechanical and thermal stress.

Compatibility Advice
  • In qualification work, validate drift, hysteresis, and response time under the real airflow, enclosure, and contamination conditions. This avoids one-off tuning in production.
  • In practice, validate the real input environment and cabling so common-mode, biasing, and protection assumptions hold in the enclosure before committing to volume builds.
  • In practice, confirm calibration and drift behavior can be measured and repeated in production rather than inferred from typical curves with the final enclosure and cabling.
Project Fit
  • A strong fit when you can verify NOSHOK, Inc. 200H-3-1-1000-6000-101 for Pressure Sensors, Transducers integration with production-like fixtures, if you need repeatable readings with a defined calibration and compensation plan across lots.
  • Not ideal when integrating NOSHOK, Inc. 200H-3-1-1000-6000-101 for Pressure Sensors, Transducers, noise and interference sources are unknown, so the error budget cannot be bounded, because repeatable production verification is not feasible.
200H-3-1-1000/6000-101200H-3-1-1000/6000-101