2AA12-N4-E

2AA12-N4-E

$504.99
  • Description:DC/DC CONVERTER
  • Series:UltraVolt® AA
  • Mfr:ULTRAVOLT / Advanced Energy
  • Package:Bulk

SKU:b85282aaed4e Category: Brand:

  
  • Quantity
    • -
    • +
  •    
ChipApex WhatsApp

Consult the customer manager about the wholesale price.

consultation hotline:86-132-6715-2157

email:chipapexlimited@gmail.com
Contact the product manager for consultation. One-stop consultation is available.


Do you want a lower wholesale price? Please send us your inquiry and we will reply immediately.

*
*
*
*
Submitting!
Submission successful!
Submission failed!
Email error!
Phone number error!

Product Detailed Parameters

  • Description:DC/DC CONVERTER
  • Series:UltraVolt® AA
  • Mfr:ULTRAVOLT / Advanced Energy
  • Package:Bulk
  • Type:High Voltage - Non-Isolated Module
  • Number of Outputs:1
  • Voltage - Input (Min):11V
  • Voltage - Input (Max):16V
  • Voltage - Output 1:0 ~ 2000V
  • Voltage - Output 2:-
  • Voltage - Output 3:-
  • Voltage - Output 4:-
  • Current - Output (Max):2mA
  • Power (Watts):4 W
  • Applications:ITE (Commercial)
  • Features:Adjustable Output, Remote On/Off
  • Operating Temperature:-40°C ~ 65°C
  • Efficiency:-
  • Mounting Type:Through Hole
  • Package / Case:11-DIP Module
  • Size / Dimension:2.97" L x 1.50" W x 0.75" H (75.4mm x 38.1mm x 19.1mm)
  • Supplier Device Package:-
  • Control Features:Enable, Active Low
  • Approval Agency:CE, cURus
  • Standard Number:-
  • Grade:-
  • Qualification:-

Download product information

2AA12-N4-E

Buying Guide
Summary

ULTRAVOLT / Advanced Energy 2AA12-N4-E is selected in DC DC Converters category when protection behavior and transient response must be validated under realistic load steps. Key specs include Description (DC/DC CONVERTER), Supply (0 ~ 2000V), Temperature (-40°C ~ 65°C), Package/case (11-DIP Module), and Mounting (Through Hole).

Selection Notes
  • For 2AA12-N4-E, validate Power (Watts) (4 W) under the expected test conditions in your application.
  • Double-check the mounting type (Through Hole) for your intended installation method.
  • Confirm the supply current (2mA) is acceptable for standby and active operation.
  • Verify the operating temperature range (-40°C ~ 65°C) and derate as needed in your application.
Alternates & Substitutions
  • For DC DC Converters, compare the datasheet test conditions behind key specs and re-check the margins that were tightest during bring-up.
  • When evaluating alternates, treat package/case 11-DIP Module, mounting Through Hole, packaging Bulk as non-negotiable unless you are re-spinning the PCB.
  • Check that supply 0 ~ 2000V, temperature -40°C ~ 65°C matches your system, then validate at corners instead of relying on typical values.
  • For regulator alternates, confirm startup sequencing, protections, and thermal performance in your actual layout.
FAQ

Who is the manufacturer of 2AA12-N4-E?
ULTRAVOLT / Advanced Energy

Any tips for derating and validation for 2AA12-N4-E?
Validate at worst-case temperature and load, confirm thermal headroom, and check protection and startup behavior with margin.

Which Power (Watts) is listed for 2AA12-N4-E?
4 W

Can you confirm the operating temperature range for 2AA12-N4-E?
-40°C ~ 65°C

Application Scenarios

Selecting ULTRAVOLT / Advanced Energy 2AA12-N4-E for DC DC Converters usually comes down to meeting the system constraints that matter most: limits, interfaces, and testability in the real build. Teams often favor power parts with clear documentation and repeatable measurement points, because bring-up depends on what can be verified. A disciplined power selection improves robustness by reducing sensitivity to layout parasitics and component tolerance. In edge servers and communications modules, multi-rail sequencing and telemetry protect compute and memory during rapid load steps. Across automotive ECUs, they handle cranking dips and load dumps while meeting EMI requirements and protecting mixed-voltage sensor domains. Layout and current loops dominate outcomes, so engineers plan for measurements like switch-node ringing and conducted emissions.

Compatibility Advice
  • To keep validation repeatable, check thermal rise after heat soak in the final enclosure, because efficiency and protection thresholds shift with temperature. This keeps acceptance criteria measurable and repeatable.
  • To keep validation repeatable, verify loop stability with the actual output capacitors and layout, because compensation and parasitics decide transient behavior during bring-up and production test.
  • In practice, confirm measurement points and test access so ripple and load-step behavior can be verified at the point of load during bring-up and production test.
Project Fit
  • Works best when you can test and document ULTRAVOLT / Advanced Energy 2AA12-N4-E for DC DC Converters integration in the final enclosure, typically when you need stable rails and predictable fault behavior under load steps and real supply variation.
2AA12-N4-E2AA12-N4-E
$504.99
Buy Now