5962-0051207QCA

5962-0051207QCA

$27.68
  • Description:IC OPAMP GP 1 CIRCUIT 14CDIP
  • Series:-
  • Mfr:Texas Instruments
  • Package:Bulk

SKU:84efb4719b07 Category: Brand:

  
  • Quantity
    • -
    • +
  •    
ChipApex WhatsApp

Consult the customer manager about the wholesale price.

consultation hotline:86-132-6715-2157

email:chipapexlimited@gmail.com
Contact the product manager for consultation. One-stop consultation is available.


Do you want a lower wholesale price? Please send us your inquiry and we will reply immediately.

*
*
*
*
Submitting!
Submission successful!
Submission failed!
Email error!
Phone number error!

Product Detailed Parameters

  • Description:IC OPAMP GP 1 CIRCUIT 14CDIP
  • Series:-
  • Mfr:Texas Instruments
  • Package:Bulk
  • Amplifier Type:General Purpose
  • Number of Circuits:1
  • Output Type:Rail-to-Rail
  • Slew Rate:1.6V/µs
  • Gain Bandwidth Product:6.4 MHz
  • Current - Input Bias:1.3 nA
  • Voltage - Input Offset:500 µV
  • Current - Supply:550µA
  • Current - Output / Channel:80 mA
  • Voltage - Supply Span (Min):2.7 V
  • Voltage - Supply Span (Max):6 V
  • Operating Temperature:-55°C ~ 125°C
  • Grade:Automotive
  • Qualification:AEC-Q100
  • Mounting Type:Through Hole
  • Package / Case:14-CDIP (0.300", 7.62mm)
  • Supplier Device Package:14-CDIP
  • -3db Bandwidth:-

Download product information

5962-0051207QCA

Buying Guide
Summary

Texas Instruments 5962-0051207QCA is used in Instrumentation, Op Amps, Buffer Amps category where bandwidth, stability, and noise behavior need to be validated in the real signal chain. Key specs include Description (IC OPAMP GP 1 CIRCUIT 14CDIP), Output type (Rail-to-Rail), Temperature (-55°C ~ 125°C), Package/case (14-CDIP (0.300", 7.62mm)), and Mounting (Through Hole).

Selection Notes
  • For 5962-0051207QCA, check Amplifier Type (General Purpose) against the datasheet conditions and your system-level constraints.
  • Double-check the mounting type (Through Hole) for your intended installation method.
  • Verify the bandwidth (6.4 MHz) covers your signal chain requirements without excessive attenuation.
Alternates & Substitutions
  • For Instrumentation, Op Amps, Buffer Amps, validate alternates under worst-case corners rather than assuming typical-only conditions represent production builds.
  • Start by confirming the physical match (package/case 14-CDIP (0.300", 7.62mm), supplier package 14-CDIP, mounting Through Hole) so the swap does not create a footprint risk.
  • When in doubt, treat the swap as an ECO: define acceptance criteria, then validate under worst-case operating corners.
  • If you want us to shortlist alternates, share your non-negotiables (package 14-CDIP (0.300", 7.62mm), interface Rail-to-Rail, frequency 6.4 MHz) plus quantity and target delivery date.
FAQ

What details help you quote 5962-0051207QCA quickly?
Send the part number (5962-0051207QCA), quantity, target delivery date, and any required packaging or documentation.

Is 5962-0051207QCA surface-mount or through-hole?
Through Hole

What is the Voltage - Supply Span (Min) of 5962-0051207QCA?
2.7 V

What Current - Output / Channel does 5962-0051207QCA have?
80 mA

Application Scenarios

In real deployments, texas Instruments 5962-0051207QCA is a common choice in Instrumentation, Op Amps, Buffer Amps applications where the goal is to keep validation repeatable and avoid edge-case surprises during bring-up. Engineers typically pay close attention to grounding, references, interface timing, and loading so end-to-end performance is preserved on the PCB. In real deployments, teams generally verify grounding, reference integrity, interface timing, and loading because small errors compound across the chain. In medical devices, low noise and predictable drift support reliable sensing over long service intervals. In real deployments, across industrial weighing and pressure systems, instrumentation amplifiers read bridge sensors over long cables, where CMRR and input protection determine usable accuracy. In medical instruments, low-drift in-amps condition biopotential and low-level sensor signals where noise and offset stability dominate the error budget. In practice, this is how teams keep performance stable without relying on fragile tuning steps.

Compatibility Advice
  • In board-level integration, verify ESD and hot-plug assumptions at the connector so transients do not latch or damage the interface. This helps field behavior stay predictable across lots.
  • Across temperature and supply corners, confirm slew rate and settling behavior under your real step sizes so system latency remains predictable. This reduces the chance that substitutions push hidden limits.
  • In board-level integration, plan test access so interface faults can be diagnosed on assembled systems without rework across temperature and supply corners.
Project Fit
  • Good fit when you can bench-verify Texas Instruments 5962-0051207QCA for Instrumentation, Op Amps, Buffer Amps integration with production-like fixtures, and you have defined bandwidth and latency targets for the sensing or measurement path.
  • Poor fit when offset, drift, or noise requirements are tight but cannot be measured in production conditions, because it becomes difficult to prove margin across production variance.
5962-0051207QCA5962-0051207QCA
$27.68
Buy Now