71M6532D-IGT/F

71M6532D-IGT/F

$4.08
  • Description:IC ENERGY METER 128KB 100-LQFP
  • Series:Single Converter Technology®
  • Mfr:Analog Devices Inc./Maxim Integrated
  • Package:Tray

SKU:d450c5e2361d Category: Brand:

  
  • Quantity
    • -
    • +
  •    
ChipApex WhatsApp

Consult the customer manager about the wholesale price.

consultation hotline:86-132-6715-2157

email:chipapexlimited@gmail.com
Contact the product manager for consultation. One-stop consultation is available.


Do you want a lower wholesale price? Please send us your inquiry and we will reply immediately.

*
*
*
*
Submitting!
Submission successful!
Submission failed!
Email error!
Phone number error!

Product Detailed Parameters

  • Description:IC ENERGY METER 128KB 100-LQFP
  • Series:Single Converter Technology®
  • Mfr:Analog Devices Inc./Maxim Integrated
  • Package:Tray
  • Input Impedance:40kOhm ~ 90kOhm
  • Measurement Error:0.10%
  • Voltage - I/O High:2V
  • Voltage - I/O Low:0.8V
  • Current - Supply:-
  • Voltage - Supply:3 V ~ 3.6 V
  • Meter Type:Single Phase, Dual Phase
  • Operating Temperature:-40°C ~ 85°C
  • Mounting Type:Surface Mount
  • Package / Case:100-LQFP
  • Supplier Device Package:100-LQFP (14x14)
  • Grade:-
  • Qualification:-

Download product information

71M6532D-IGT/F

Buying Guide
Summary

Analog Devices Inc./Maxim Integrated 71M6532D-IGT-F is a component in Energy Metering category typically evaluated for fit, operating limits, and supportability in production. Key specs include Description (IC ENERGY METER 128KB 100-LQFP), Series (Single Converter Technology®), Packaging (Tray), Supply (3 V ~ 3.6 V), and Temperature (-40°C ~ 85°C).

Selection Notes
  • For 71M6532D-IGT-F, confirm the operating temperature range (-40°C ~ 85°C) meets your deployment conditions.
  • Validate Voltage - I/O High (2V) under the expected test conditions in your application.
  • Make sure the mounting type (Surface Mount) matches how the part will be installed and inspected.
  • Confirm the characteristic impedance (40kOhm ~ 90kOhm) matches your transmission line and matching network.
Alternates & Substitutions
  • For Energy Metering, compare the datasheet test conditions behind key specs and re-check the margins that were tightest during bring-up.
  • Before looking at performance tables, lock package/case 100-LQFP, supplier package 100-LQFP (14x14), mounting Surface Mount and verify the system envelope (supply 3 V ~ 3.6 V, temperature -40°C ~ 85°C) to avoid a non-drop-in swap.
  • When in doubt, treat the swap as an ECO: define acceptance criteria, then validate under worst-case operating corners.
  • If you want us to shortlist alternates, share your non-negotiables (package 100-LQFP, supply 3 V ~ 3.6 V) plus quantity and target delivery date.
FAQ

How do I confirm compatibility for 71M6532D-IGT-F?
Match mechanical footprint first, then verify electrical limits and operating conditions against your system constraints.

Is 71M6532D-IGT-F surface-mount or through-hole?
Surface Mount

What Voltage - I/O Low is listed for 71M6532D-IGT-F?
0.8V

What is the operating temperature range of 71M6532D-IGT-F?
-40°C ~ 85°C

Application Scenarios

Analog Devices Inc./Maxim Integrated 71M6532D-IGT-F is listed under the Energy Metering category and is commonly used when correctness, reliability, and qualification repeatability matter. In real deployments, board-level parasitics and source/load impedance often dominate, so teams validate the complete chain rather than isolated blocks. End-to-end behavior depends on references, layout, filtering, and the real impedance environment, so verification is done on the assembled PCB. In practice, within automotive sensing, mixed-signal paths survive transients and vibration while maintaining stable measurement margins. Within smart energy meters, metering ICs and front ends measure voltage/current with calibrated phase accuracy across a wide dynamic range and temperature. Across industrial power distribution, metering supports load profiling and fault analysis where EMI and surge resilience on mains-connected inputs is essential. In real deployments, repeatability across temperature, load, and noise is what keeps performance consistent.

Compatibility Advice
  • To avoid late surprises, confirm interface timing and voltage levels against the MCU/DSP/FPGA so digital margins do not limit analog performance. This reduces the chance that substitutions push hidden limits.
Project Fit
  • Ideal when you can measure and verify Analog Devices Inc./Maxim Integrated 71M6532D-IGT-F for Energy Metering integration on the assembled PCB, if you can calibrate and test the chain consistently across production lots.
  • Usually not a good fit when integrating Analog Devices Inc./Maxim Integrated 71M6532D-IGT-F for Energy Metering, production test access is too limited to verify the key performance metrics, because it becomes difficult to prove margin across production variance.
71M6532D-IGT/F71M6532D-IGT/F
$4.08
Buy Now