  • Description:SENSOR NITROGEN DIOXIDE 0-3V OUT
  • Series:-
  • Mfr:SPEC Sensors (a division of Interlink Electronics)
  • Package:Bulk

SKU:9aef1068a881 Category: Brand:

  
  • Quantity
    • -
    • +
  •    
ChipApex WhatsApp

Consult the customer manager about the wholesale price.

consultation hotline:86-132-6715-2157

email:chipapexlimited@gmail.com
Contact the product manager for consultation. One-stop consultation is available.


Do you want a lower wholesale price? Please send us your inquiry and we will reply immediately.

*
*
*
*
Submitting!
Submission successful!
Submission failed!
Email error!
Phone number error!

Product Detailed Parameters

  • Description:SENSOR NITROGEN DIOXIDE 0-3V OUT
  • Series:-
  • Mfr:SPEC Sensors (a division of Interlink Electronics)
  • Package:Bulk
  • Type:Nitrogen Dioxide (NO2)
  • Accuracy:±2%
  • Output:0 V ~ 3 V
  • Operating Temperature:-40°C ~ 50°C
  • Voltage - Supply:2.7V ~ 3.3V
  • Current - Supply:15µA
  • Oxygen Range:-

Download product information

968-004

Buying Guide
Summary

SPEC Sensors (a division of Interlink Electronics) 968-004 is selected in Gas Sensors category when calibration, drift, and environment constraints must be validated early. Key specs include Description (SENSOR NITROGEN DIOXIDE 0-3V OUT), Type (Nitrogen Dioxide (NO2)), and Temperature (-40°C ~ 50°C).

Selection Notes
  • For 968-004, verify Current - Supply (15µA) matches your requirements and the datasheet test conditions.
  • Ensure the supply current (15µA) is acceptable for battery life and thermal limits.
  • Ensure the output type (0 V ~ 3 V) is compatible with the downstream interface.
  • Confirm the operating temperature range (-40°C ~ 50°C) meets your deployment conditions.
Alternates & Substitutions
  • For Gas Sensors, treat alternates as an integration task and validate the assumptions that matter on the assembled system.
  • Begin with the constraints that are hardest to change later: packaging Bulk.
  • Make sure the alternate stays inside your system envelope: supply 2.7V ~ 3.3V, temperature -40°C ~ 50°C.
  • Confirm compliance/qualification needs (for example RoHS/REACH or grade) before approving a second source for production.
FAQ

Which Accuracy is specified for 968-004?
±2%

What is the Output of 968-004?
0 V ~ 3 V

What supply voltage range does 968-004 require?
2.7V ~ 3.3V

Which supply current is specified for 968-004?
15µA

Application Scenarios

For SPEC Sensors (a division of Interlink Electronics) 968-004 used in Gas Sensors designs, the shortlist is often driven by predictable margins and a straightforward validation plan. Reliable environmental sensing enables better automation decisions and reduces operational risk. In practice, they monitor conditions such as temperature, humidity, light, gas concentration, or particulates for safety and efficiency. Within smart buildings, environmental sensors drive HVAC optimization across dusty airflow and changing installation conditions. In safety and air-quality monitoring, gas and smoke sensing is qualified for drift and contamination because false alarms and misses are costly. In indoor safety systems, gas and smoke sensing is validated for response time and long-term drift under variable airflow. In real deployments, gas and smoke sensing is validated for drift, contamination, and calibration flow because long-term stability dominates real deployments.

Compatibility Advice
  • During bring-up and production test, check filtering and bandwidth choices so noise and latency align with the control or monitoring use-case. This avoids one-off tuning in production.
  • Before freezing the BOM, check filtering and bandwidth choices so noise and latency align with the control or monitoring use-case. This keeps integration from depending on typical-only conditions.
  • To keep validation repeatable, verify long-term stability and condensation exposure if the product sees outdoor or humid environments before freezing the BOM.