A10-APS

A10-APS

$149.39
  • Description:A-10 Analog Pressure Sensor
  • Series:-
  • Mfr:Atlas Scientific
  • Package:Bulk

SKU:926bfbc8fcb6 Category: Brand:

  
  • Quantity
    • -
    • +
  •    
ChipApex WhatsApp

Consult the customer manager about the wholesale price.

consultation hotline:86-132-6715-2157

email:chipapexlimited@gmail.com
Contact the product manager for consultation. One-stop consultation is available.


Do you want a lower wholesale price? Please send us your inquiry and we will reply immediately.

*
*
*
*
Submitting!
Submission successful!
Submission failed!
Email error!
Phone number error!

Product Detailed Parameters

  • Description:A-10 Analog Pressure Sensor
  • Series:-
  • Mfr:Atlas Scientific
  • Package:Bulk
  • Applications:-
  • Pressure Type:-
  • Operating Pressure:10PSI (68.95kPa)
  • Output Type:Analog Voltage
  • Output:0.5 V ~ 4.5 V
  • Accuracy:±0.1PSI (0.69kPa)
  • Voltage - Supply:5V
  • Port Size:Male - 1/4" (6.35mm) NPT
  • Port Style:Threaded
  • Features:-
  • Termination Style:Cable Leads
  • Maximum Pressure:30PSI (206.84kPa)
  • Operating Temperature:-40°C ~ 105°C
  • Mounting Type:-
  • Package / Case:Cylinder, Threaded
  • Supplier Device Package:-
  • Grade:-
  • Qualification:-

Download product information

A10-APS

Buying Guide
Summary

Atlas Scientific A10-APS is used in Pressure Sensors, Transducers category where placement, interface fit, and operating envelope drive measurement reliability. Key specs include Description (A-10 Analog Pressure Sensor), Output type (Analog Voltage), Temperature (-40°C ~ 105°C), and Package/case (Cylinder, Threaded).

Selection Notes
  • For A10-APS, confirm Port Style (Threaded) is suitable for your use case and operating conditions.
  • Confirm the package/case (Cylinder, Threaded) matches your PCB footprint and land pattern.
  • Check the required supply voltage (5V) and allow margin for tolerance and transients.
  • Verify the output type (Analog Voltage) and any logic-level requirements in your design.
Alternates & Substitutions
  • For Pressure Sensors, Transducers, treat alternates as an integration task and validate the assumptions that matter on the assembled system.
  • Then confirm the operating envelope (supply 5V, temperature -40°C ~ 105°C) with margin for transients and derating.
  • Confirm compliance/qualification needs (for example RoHS/REACH or grade) before approving a second source for production.
  • Before approving a second source, compare the functional mode matrix and the test conditions behind the marketing headline specs.
FAQ

Who is the manufacturer of A10-APS?
Atlas Scientific

How do I validate sensor performance for A10-APS?
Test with real fixtures and environmental conditions, then confirm calibration, drift, and noise behavior meet your requirements.

What output type does A10-APS have?
Analog Voltage

What is the packaging of A10-APS?
Bulk

Application Scenarios

In production Pressure Sensors, Transducers builds, parts like Atlas Scientific A10-APS are shortlisted for predictable behavior, clear documentation, and stable supply. Reliable environmental sensing enables better automation decisions and reduces operational risk. They monitor conditions such as temperature, humidity, light, gas concentration, or particulates for safety and efficiency. In agriculture, humidity and particulate sensing supports greenhouse automation where condensation is common. In agriculture, humidity and particulate sensing supports greenhouse automation where condensation and contaminants are common. In real deployments, across data centers, distributed sensing improves hot-spot detection in constrained airflow channels between high-density racks. In real deployments, pressure sensing emphasizes porting, response time, drift, and compensation so accuracy remains stable under real mechanical and thermal stress.

Compatibility Advice
  • With the final enclosure and cabling, check filtering and bandwidth choices so noise and latency align with the control or monitoring use-case. This keeps acceptance criteria measurable and repeatable.
  • For compatibility, validate the real input environment and cabling so common-mode, biasing, and protection assumptions hold in the enclosure. This keeps integration from depending on typical-only conditions.
  • In board-level integration, validate noise and latency with production-like cabling so the system behaves the same outside the lab. This helps field behavior stay predictable across lots.
Project Fit
  • Best fit when you can bench-verify Atlas Scientific A10-APS for Pressure Sensors, Transducers integration in the final enclosure, if you can measure error budgets and environmental drift so acceptance criteria are objective. On the other hand, a weaker fit when integrating Atlas Scientific A10-APS for Pressure Sensors, Transducers, calibration and drift cannot be supported but long-term accuracy is still expected, because the integration depends on constraints that cannot be controlled across builds.
A10-APSA10-APS
$149.39
Buy Now