AE10-UW-S5

AE10-UW-S5

$83.35
  • Description:DC DC CONVERTER 5V 10W
  • Series:AE10-UW (10W)
  • Mfr:CUI Inc.
  • Package:Tray

SKU:17a1ab8b3fac Category: Brand:

  
  • Quantity
    • -
    • +
  •    
ChipApex WhatsApp

Consult the customer manager about the wholesale price.

consultation hotline:86-132-6715-2157

email:chipapexlimited@gmail.com
Contact the product manager for consultation. One-stop consultation is available.


Do you want a lower wholesale price? Please send us your inquiry and we will reply immediately.

*
*
*
*
Submitting!
Submission successful!
Submission failed!
Email error!
Phone number error!

Product Detailed Parameters

  • Description:DC DC CONVERTER 5V 10W
  • Series:AE10-UW (10W)
  • Mfr:CUI Inc.
  • Package:Tray
  • Type:Isolated Module
  • Number of Outputs:1
  • Voltage - Input (Min):200V
  • Voltage - Input (Max):1500V
  • Voltage - Output 1:5V
  • Voltage - Output 2:-
  • Voltage - Output 3:-
  • Voltage - Output 4:-
  • Current - Output (Max):2A
  • Power (Watts):10 W
  • Voltage - Isolation:4 kV
  • Applications:ITE (Commercial)
  • Features:OCP, OVP, SCP
  • Operating Temperature:-40°C ~ 70°C (With Derating)
  • Efficiency:64%
  • Mounting Type:Through Hole
  • Package / Case:5-DIP Module
  • Size / Dimension:4.92" L x 2.95" W x 1.57" H (125.0mm x 75.0mm x 40.0mm)
  • Supplier Device Package:-
  • Control Features:-
  • Approval Agency:CSA
  • Standard Number:C22.2 No. 107.1-01
  • Grade:-
  • Qualification:-

Download product information

AE10-UW-S5

Buying Guide
Summary

CUI Inc. AE10-UW-S5 is used in DC DC Converters category in power designs where stability, startup behavior, and thermal headroom need to be measurable. Key specs include Description (DC DC CONVERTER 5V 10W), Temperature (-40°C ~ 70°C (With Derating)), Package/case (5-DIP Module), Mounting (Through Hole), and Packaging (Tray).

Selection Notes
  • For AE10-UW-S5, verify the operating temperature range (-40°C ~ 70°C (With Derating)) and derate as needed in your application.
  • Double-check Standard Number (C22.2 No. 107.1-01) against your specification and operating conditions.
  • Double-check the mounting type (Through Hole) for your intended installation method.
Alternates & Substitutions
  • For DC DC Converters, treat alternates as an integration task and validate the assumptions that matter on the assembled system.
  • Before looking at performance tables, lock package/case 5-DIP Module, mounting Through Hole, packaging Tray and verify the system envelope (temperature -40°C ~ 70°C (With Derating)) to avoid a non-drop-in swap.
  • For power parts, match input/output limits first, then validate stability, protection behavior, and thermals under load steps and transients.
  • Compare not just numbers but also the conditions: rails, loads, timing, and temperature points behind the spec table.
FAQ

Which Voltage - Isolation is specified for AE10-UW-S5?
4 kV

What is the Applications of AE10-UW-S5?
ITE (Commercial)

What is the Voltage - Output 1 of AE10-UW-S5?
5V

Can you confirm the packaging for AE10-UW-S5?
Tray

Application Scenarios

Across many DC DC Converters builds, CUI Inc. AE10-UW-S5 is reviewed for predictable behavior, supportability, and stable qualification evidence. Layout and current loops dominate outcomes, so engineers plan for measurements like switch-node ringing and conducted emissions. Within production power domains, predictable startup and fault behavior often matter more than peak efficiency numbers on paper. A well-chosen power solution reduces nuisance resets and shortens debug cycles by keeping rails inside margin across corners. Within building automation, predictable rails prevent nuisance resets and simplify field service across distributed nodes. Within automotive body electronics, converters must be robust to harness noise and intermittent load changes without injecting audible or RF interference. In industrial PLCs and gateways, power stages convert 24 V buses into low-noise rails inside sealed enclosures where surges and heat are common.

Compatibility Advice
  • In qualification work, confirm measurement points and test access so ripple and load-step behavior can be verified at the point of load. This reduces the chance that substitutions push hidden limits.
  • For production stability, check thermal rise after heat soak in the final enclosure, because efficiency and protection thresholds shift with temperature. This keeps acceptance criteria measurable and repeatable.
Project Fit
  • Ideal when you can test and document CUI Inc. AE10-UW-S5 for DC DC Converters integration under realistic load and noise, and you need predictable rails under load steps and can validate stability, EMI, and thermal rise in the final layout.
AE10-UW-S5AE10-UW-S5