AZ761-1A-60DEK

AZ761-1A-60DEK

$1.45
  • Description:RELAY GEN PURPOSE SPST 12A 60V
  • Series:AZ761
  • Mfr:American Zettler
  • Package:Box

SKU:7c4d722ed4b2 Category: Brand:

  
  • Quantity
    • -
    • +
  •    
ChipApex WhatsApp

Consult the customer manager about the wholesale price.

consultation hotline:86-132-6715-2157

email:chipapexlimited@gmail.com
Contact the product manager for consultation. One-stop consultation is available.


Do you want a lower wholesale price? Please send us your inquiry and we will reply immediately.

*
*
*
*
Submitting!
Submission successful!
Submission failed!
Email error!
Phone number error!

Product Detailed Parameters

  • Description:RELAY GEN PURPOSE SPST 12A 60V
  • Series:AZ761
  • Mfr:American Zettler
  • Package:Box
  • Mounting Type:Through Hole
  • Coil Voltage:60VDC
  • Contact Form:SPST-NO (1 Form A)
  • Contact Rating (Current):12:00 AM
  • Switching Voltage:440VAC, 125VDC - Max
  • Load - Max Switching:3324VA, 360W
  • Coil Current:8 mA
  • Coil Type:Non Latching
  • Features:-
  • Termination Style:PC Pin
  • Seal Rating:Sealed - Fully
  • Coil Insulation:Class F
  • Must Operate Voltage:42 VDC
  • Must Release Voltage:6 VDC
  • Operating Temperature:-40°C ~ 85°C
  • Contact Material:-
  • Approval Agency:CUR, UL, VDE
  • Relay Type:General Purpose
  • Grade:-
  • Qualification:-
  • Operate Time:15 ms
  • Release Time:8 ms

Download product information

AZ761-1A-60DEK

Buying Guide
Summary

American Zettler AZ761-1A-60DEK is evaluated in Power Relays, Over 2 Amps category where failure modes and qualification evidence matter as much as headline ratings. Key specs include Description (RELAY GEN PURPOSE SPST 12A 60V), Temperature (-40°C ~ 85°C), Mounting (Through Hole), and Packaging (Box).

Selection Notes
  • For AZ761-1A-60DEK, check Release Time (8 ms) against the datasheet conditions and your system-level constraints.
  • Verify the switch configuration (SPST-NO (1 Form A)) is correct for your intended control path.
  • Confirm the contact rating (12:00 AM) handles your worst-case switching current and inrush.
Alternates & Substitutions
  • In Power Relays, Over 2 Amps, confirm that alternates preserve startup states and fault behavior so system behavior does not change quietly.
  • Confirm the real operating corners (temperature -40°C ~ 85°C) and avoid swaps that only work at typical conditions.
  • For relays/switches, match contact form SPST-NO (1 Form A), coil 60VDC, contact rating 12:00 AM and derate for inductive loads and inrush current.
  • If substitutions are likely, write down the non-negotiables and re-check them when the supply chain changes, not after field failures.
FAQ

How do I choose an alternate for AZ761-1A-60DEK?
Match footprint and ratings first, then confirm operating conditions and test conditions behind key specs before approval.

What Must Operate Voltage is listed for AZ761-1A-60DEK?
42 VDC

What Operate Time is listed for AZ761-1A-60DEK?
15 ms

What Approval Agency is listed for AZ761-1A-60DEK?
CUR, UL, VDE

Application Scenarios

American Zettler AZ761-1A-60DEK in the Power Relays, Over 2 Amps category is typically selected when engineers need predictable, spec-driven behavior in a production design. In real deployments, designers often balance lifetime, inrush behavior, leakage, and environmental sealing depending on load type and duty cycle. They are often selected based on safety requirements, mechanical constraints, and real-world switching stress. Within field equipment, sealing and contact materials determine long-term reliability under dust and moisture. In real deployments, across outdoor kiosks and ticketing, sealing and corrosion resistance prevent intermittent failures caused by condensation and pollutants. In manufacturing test fixtures, predictable switching behavior improves measurement repeatability across high cycle counts. In many programs, a focused validation plan surfaces the real risks earlier than additional schematic iteration. The design becomes easier to validate when the key assumptions are explicit and measurable.

Compatibility Advice
  • For Power Relays, Over 2 Amps, to avoid late surprises, coordinate switching and protection so fault cases fail safe rather than creating nuisance trips or unsafe states. This keeps qualification evidence reproducible later.
Project Fit
  • Not ideal when integrating American Zettler AZ761-1A-60DEK for Power Relays, Over 2 Amps, inductive transients are unbounded and protection is not coordinated, because the behavior cannot be verified in a repeatable way.
AZ761-1A-60DEKAZ761-1A-60DEK
$1.45
Buy Now