CLA30MT1200NPZ-TRL

CLA30MT1200NPZ-TRL

$6.03
  • Description:TRIAC 1.2KV 33A TO263HV
  • Series:DT-Triac™

SKU:b40039600ec6 Category: Brand:

  
  • Quantity
    • -
    • +
  •    
ChipApex WhatsApp

Consult the customer manager about the wholesale price.

consultation hotline:86-132-6715-2157

email:chipapexlimited@gmail.com
Contact the product manager for consultation. One-stop consultation is available.


Do you want a lower wholesale price? Please send us your inquiry and we will reply immediately.

*
*
*
*
Submitting!
Submission successful!
Submission failed!
Email error!
Phone number error!

Product Detailed Parameters

  • Description:TRIAC 1.2KV 33A TO263HV
  • Series:DT-Triac™
  • Mfr:IXYS
  • Package:Tape & Reel (TR),Cut Tape (CT)
  • Triac Type:Standard
  • Voltage - Off State:1.2 kV
  • Current - On State (It (RMS)) (Max):33 A
  • Voltage - Gate Trigger (Vgt) (Max):1.3 V
  • Current - Non Rep. Surge 50, 60Hz (Itsm):170A, 185A
  • Current - Gate Trigger (Igt) (Max):40 mA
  • Current - Hold (Ih) (Max):50 mA
  • Configuration:Single
  • Operating Temperature:-40°C ~ 150°C (TJ)
  • Mounting Type:Surface Mount
  • Package / Case:TO-263-3, D2PAK (2 Leads + Tab), TO-263AB
  • Supplier Device Package:TO-263HV
  • Grade:-
  • Qualification:-

Download product information

CLA30MT1200NPZ-TRL

Buying Guide
Summary

IXYS CLA30MT1200NPZ-TRL is sourced in TRIACs category when teams want clear constraints and a repeatable validation path. Key specs include Description (TRIAC 1.2KV 33A TO263HV), Series (DT-Triac™), Packaging (Tape & Reel (TR), Cut Tape (CT)), Temperature (-40°C ~ 150°C (TJ)), and Package/case (TO-263-3, D2PAK (2 Leads + Tab), TO-263AB).

Selection Notes
  • For CLA30MT1200NPZ-TRL, verify the package/case (TO-263-3, D2PAK (2 Leads + Tab), TO-263AB) fits your mechanical constraints and assembly process.
  • Make sure the supply current (33 A) fits your power budget in all modes.
  • Validate the operating temperature range (-40°C ~ 150°C (TJ)) for your environment and margin.
Alternates & Substitutions
  • For TRIACs, treat alternates as an integration task and validate the assumptions that matter on the assembled system.
  • Before looking at performance tables, lock package/case TO-263-3, D2PAK (2 Leads + Tab), TO-263AB, supplier package TO-263HV, mounting Surface Mount and verify the system envelope (temperature -40°C ~ 150°C (TJ)) to avoid a non-drop-in swap.
  • For production substitutions, confirm traceability and documentation expectations so the alternate can be released cleanly.
  • Always compare the datasheet test conditions behind key specs (load, frequency, temperature) to avoid swapping in a part that was characterized differently.
FAQ

What should I verify before using CLA30MT1200NPZ-TRL in production?
Confirm footprint/pinout, min/max ratings, operating temperature, and the datasheet test conditions behind key specifications.

Which Current - Hold (Ih) (Max) is specified for CLA30MT1200NPZ-TRL?
50 mA

What is the Triac Type of CLA30MT1200NPZ-TRL?
Standard

Which Voltage - Gate Trigger (Vgt) (Max) is listed for CLA30MT1200NPZ-TRL?
1.3 V

Application Scenarios

For many TRIACs designs, IXYS CLA30MT1200NPZ-TRL is vetted against electrical margins, thermal headroom, and mechanical integration before the BOM is frozen. They are often used in rectifier and steering paths where surge handling and leakage under temperature decide reliability. Correct clamping and rectification parts reduce downtime and prevent cascading damage. Across consumer adapters, clamping and recovery behavior influence reliability during hot-plug and surge stress. Within low-noise designs, leakage and recovery behavior can affect measurement accuracy and must be validated. In practice, within industrial power supplies and rectifiers, diode stages handle repetitive stress where thermal paths and mounting quality dominate long-term reliability.

Compatibility Advice
  • Before release to production, validate recovery, dv/dt, and commutation interactions with wiring inductance so ringing and overvoltage are controlled. This keeps acceptance criteria measurable and repeatable.
  • Validate recovery, dv/dt, and commutation interactions with wiring inductance so ringing and overvoltage are controlled before committing to volume builds.
  • In practice, check thermal paths and mounting so junction temperature remains predictable under the real current waveform. This avoids one-off tuning in production.
Project Fit
  • Best fit when you can test and document IXYS CLA30MT1200NPZ-TRL for TRIACs integration under realistic load and noise, if you can control creepage/clearance and thermal paths so margins remain stable after heat soak. On the other hand, less ideal when integrating IXYS CLA30MT1200NPZ-TRL for TRIACs, fault coordination and acceptance criteria are not defined, leaving protection behavior fragile, because the integration depends on constraints that cannot be controlled across builds.
CLA30MT1200NPZ-TRLCLA30MT1200NPZ-TRL
$6.03
Buy Now