FMA-500-T1-05W-GV

FMA-500-T1-05W-GV

$57.77
  • Description:SENSOR 0.18PSI 1/8"NPT 4.5V
  • Series:FMA
  • Mfr:Amphenol Advanced Sensors (NovaSensor)
  • Package:Bulk

SKU:bc3149f657b6 Category: Brand:

  
  • Quantity
    • -
    • +
  •    
ChipApex WhatsApp

Consult the customer manager about the wholesale price.

consultation hotline:86-132-6715-2157

email:chipapexlimited@gmail.com
Contact the product manager for consultation. One-stop consultation is available.


Do you want a lower wholesale price? Please send us your inquiry and we will reply immediately.

*
*
*
*
Submitting!
Submission successful!
Submission failed!
Email error!
Phone number error!

Product Detailed Parameters

  • Description:SENSOR 0.18PSI 1/8"NPT 4.5V
  • Series:FMA
  • Mfr:Amphenol Advanced Sensors (NovaSensor)
  • Package:Bulk
  • Applications:Board Mount
  • Pressure Type:Vacuum
  • Operating Pressure:0.18PSI (1.25kPa)
  • Output Type:Analog Voltage
  • Output:0.5 V ~ 4.5 V
  • Accuracy:±2.5%
  • Voltage - Supply:4.75V ~ 5.25V
  • Port Size:Female - 1/8" (3.18mm) NPT
  • Port Style:Barbless
  • Features:Amplified Output, Temperature Compensated
  • Termination Style:Connector
  • Maximum Pressure:0.36PSI (2.49kPa)
  • Operating Temperature:-40°C ~ 125°C
  • Mounting Type:-
  • Package / Case:Module
  • Supplier Device Package:-

Download product information

FMA-500-T1-05W-GV

Buying Guide
Summary

Amphenol Advanced Sensors (NovaSensor) FMA-500-T1-05W-GV is selected in Pressure Sensors, Transducers category when calibration, drift, and environment constraints must be validated early. Key specs include Description (SENSOR 0.18PSI 1/8"NPT 4.5V), Output type (Analog Voltage), Temperature (-40°C ~ 125°C), and Package/case (Module).

Selection Notes
  • For FMA-500-T1-05W-GV, confirm the operating temperature range (-40°C ~ 125°C) meets your deployment conditions.
  • Validate Maximum Pressure (0.36PSI (2.49kPa)) under the expected test conditions in your application.
  • Double-check the package/case (Module) and recommended land pattern before ordering.
  • Verify your power rails meet the supply requirement (4.75V ~ 5.25V) under worst-case conditions.
Alternates & Substitutions
  • For Pressure Sensors, Transducers substitutions, lock footprint/pinout and operating envelope first, then verify the critical performance conditions on your hardware.
  • Confirm the physical match (package/case Module, packaging Bulk) and the operating corners (supply 4.75V ~ 5.25V, temperature -40°C ~ 125°C) so the substitution is not a hidden redesign.
  • If you are qualifying a second source, align documentation/traceability requirements early to avoid surprises in procurement.
  • To speed up alternate matching, provide your must-have constraints (package Module, supply 4.75V ~ 5.25V, interface Analog Voltage) and any compliance/traceability needs.
FAQ

What details help you quote FMA-500-T1-05W-GV quickly?
Share the part number (FMA-500-T1-05W-GV), quantity, target delivery date, and any packaging or documentation requirements.

Which Maximum Pressure is listed for FMA-500-T1-05W-GV?
0.36PSI (2.49kPa)

Which supply voltage range is specified for FMA-500-T1-05W-GV?
4.75V ~ 5.25V

Which package/case is listed for FMA-500-T1-05W-GV?
Module

Application Scenarios

For Amphenol Advanced Sensors (NovaSensor) FMA-500-T1-05W-GV in the Pressure Sensors, Transducers category, teams usually prioritize documentation clarity and repeatable behavior in production. They monitor conditions such as temperature, humidity, light, gas concentration, or particulates for safety and efficiency. Designers typically evaluate response time, drift, contamination resistance, and compensation so readings stay meaningful over time. Pressure sensing emphasizes porting, response time, drift, and compensation so accuracy remains stable under real mechanical and thermal stress. In real deployments, after interfaces and margins are defined, teams validate the design on the actual board rather than relying on typical conditions. In industrial process lines, temperature and gas monitoring supports operator safety near ovens and tanks. Across industrial process lines, temperature and gas monitoring protects operators near ovens, tanks, or clean rooms with strict calibration rules. It also makes bring-up and troubleshooting easier by keeping behavior aligned with what can be validated on the bench.

Compatibility Advice
  • For second-source planning, verify environmental stress assumptions (temperature, humidity, contamination) so sensing remains repeatable over life. This avoids one-off tuning in production.
Project Fit
  • Strongest fit when you can test and document Amphenol Advanced Sensors (NovaSensor) FMA-500-T1-05W-GV for Pressure Sensors, Transducers integration across temperature and supply corners, and you need repeatable readings with a defined calibration and compensation plan across lots.
  • Riskier when integrating Amphenol Advanced Sensors (NovaSensor) FMA-500-T1-05W-GV for Pressure Sensors, Transducers, calibration and compensation cannot be supported but long-term accuracy is still expected, because the behavior cannot be verified in a repeatable way.
FMA-500-T1-05W-GVFMA-500-T1-05W-GV