NPA-100B-015G

NPA-100B-015G

$15.43
  • Description:SENSOR 15PSIG 0.12" .166V
  • Series:NPA-100
  • Mfr:Amphenol Advanced Sensors (NovaSensor)
  • Package:Tape & Reel (TR)

SKU:bb48013f3560 Category: Brand:

  
  • Quantity
    • -
    • +
  •    
ChipApex WhatsApp

Consult the customer manager about the wholesale price.

consultation hotline:86-132-6715-2157

email:chipapexlimited@gmail.com
Contact the product manager for consultation. One-stop consultation is available.


Do you want a lower wholesale price? Please send us your inquiry and we will reply immediately.

*
*
*
*
Submitting!
Submission successful!
Submission failed!
Email error!
Phone number error!

Product Detailed Parameters

  • Description:SENSOR 15PSIG 0.12" .166V
  • Series:NPA-100
  • Mfr:Amphenol Advanced Sensors (NovaSensor)
  • Package:Tape & Reel (TR)
  • Applications:Board Mount
  • Pressure Type:Vented Gauge
  • Operating Pressure:15PSI (103.42kPa)
  • Output Type:Analog Voltage
  • Output:100 mV ~ 166 mV
  • Accuracy:±1.5%
  • Voltage - Supply:-
  • Port Size:Male - 0.12" (3mm) Tube, Dual
  • Port Style:Barbed
  • Features:-
  • Termination Style:Gull Wing
  • Maximum Pressure:60PSI (413.69kPa)
  • Operating Temperature:-40°C ~ 125°C
  • Mounting Type:Surface Mount
  • Package / Case:14-SOIC Module, Top Port
  • Supplier Device Package:-

Download product information

NPA-100B-015G

Buying Guide
Summary

Amphenol Advanced Sensors (NovaSensor) NPA-100B-015G is selected in Pressure Sensors, Transducers category when calibration, drift, and environment constraints must be validated early. Key specs include Description (SENSOR 15PSIG 0.12" .166V), Output type (Analog Voltage), Temperature (-40°C ~ 125°C), Package/case (14-SOIC Module, Top Port), and Mounting (Surface Mount).

Selection Notes
  • For NPA-100B-015G, make sure the mounting type (Surface Mount) matches how the part will be installed and inspected.
  • Ensure the output type (Analog Voltage) is compatible with the downstream interface.
  • Confirm the operating temperature range (-40°C ~ 125°C) meets your deployment conditions.
  • Validate Termination Style (Gull Wing) under the expected test conditions in your application.
Alternates & Substitutions
  • For Pressure Sensors, Transducers, validate alternates under worst-case corners rather than assuming typical-only conditions represent production builds.
  • Lock the mechanical constraints first (package/case 14-SOIC Module, Top Port, mounting Surface Mount, packaging Tape & Reel (TR)) before comparing performance specs.
  • Validate the min/max operating conditions (temperature -40°C ~ 125°C) and keep headroom for worst-case corners.
  • If you are qualifying a second source, align documentation/traceability requirements early to avoid surprises in procurement.
FAQ

Who is the manufacturer of NPA-100B-015G?
Amphenol Advanced Sensors (NovaSensor)

Which Port Size is listed for NPA-100B-015G?
Male - 0.12" (3mm) Tube, Dual

What Applications does NPA-100B-015G have?
Board Mount

Can you confirm the Maximum Pressure for NPA-100B-015G?
60PSI (413.69kPa)

Application Scenarios

In real deployments, the question for Amphenol Advanced Sensors (NovaSensor) NPA-100B-015G in Pressure Sensors, Transducers is whether it stays inside the electrical/thermal envelope while remaining easy to validate and support. They monitor conditions such as temperature, humidity, light, gas concentration, or particulates for safety and efficiency. Designers generally evaluate response time, drift, contamination resistance, and compensation so readings stay meaningful over time. Pressure sensing emphasizes porting, response time, drift, and compensation so accuracy remains stable under real mechanical and thermal stress. Once the boundaries are clear, it becomes easier to judge fit in the target application and test it on real hardware. In agriculture, humidity and particulate sensing supports greenhouse automation where condensation is common. In data centers, distributed sensing improves hot-spot detection in constrained airflow channels between high-density racks. Over the product lifecycle, it reduces maintenance burden by keeping behavior spec-driven and testable.

Compatibility Advice
  • Verify environmental stress assumptions (temperature, humidity, contamination) so sensing remains repeatable over life with the real source, load, and wiring.
  • In qualification work, confirm calibration and compensation strategy so readings stay repeatable across production lots. This keeps integration from depending on typical-only conditions.
Project Fit
  • Works best when you can bench-verify Amphenol Advanced Sensors (NovaSensor) NPA-100B-015G for Pressure Sensors, Transducers integration in the final enclosure, especially if you need repeatable readings with a defined calibration and compensation plan across lots.
  • More fragile when integrating Amphenol Advanced Sensors (NovaSensor) NPA-100B-015G for Pressure Sensors, Transducers, the input environment is poorly controlled and cannot be replicated for validation, because the behavior cannot be verified in a repeatable way.
NPA-100B-015GNPA-100B-015G
$15.43
Buy Now