  • Description:High Performance Fixed Range Pre
  • Series:PT30
  • Mfr:NOSHOK, Inc.
  • Package:Tape & Box (TB)

SKU:70bb121ffc45 Category: Brand:

  
  • Quantity
    • -
    • +
  •    
ChipApex WhatsApp

Consult the customer manager about the wholesale price.

consultation hotline:86-132-6715-2157

email:chipapexlimited@gmail.com
Contact the product manager for consultation. One-stop consultation is available.


Do you want a lower wholesale price? Please send us your inquiry and we will reply immediately.

*
*
*
*
Submitting!
Submission successful!
Submission failed!
Email error!
Phone number error!

Product Detailed Parameters

  • Description:High Performance Fixed Range Pre
  • Series:PT30
  • Mfr:NOSHOK, Inc.
  • Package:Tape & Box (TB)
  • Applications:Industrial
  • Pressure Type:Compound
  • Operating Pressure:0PSI ~ 100PSI (0kPa ~ 689.48kPa)
  • Output Type:Analog Current, Analog Voltage
  • Output:4 mA ~ 20 mA
  • Accuracy:±0.25%
  • Voltage - Supply:-
  • Port Size:Male - 7/16" (11.11mm) SAE
  • Port Style:Threaded
  • Features:-
  • Termination Style:DIN EN 175301-803 Form C with 3' Cable
  • Operating Temperature:-30°C ~ 100°C
  • Mounting Type:-
  • Package / Case:-
  • Supplier Device Package:-
  • Grade:-
  • Qualification:-

Download product information

PT30-100psic-1-1-50-17-ST8

Buying Guide
Summary

NOSHOK, Inc. PT30-100PSIC-1-1-50-17-ST8 is used in Pressure Sensors, Transducers category where placement, interface fit, and operating envelope drive measurement reliability. Key specs include Description (High Performance Fixed Range Pre), Output type (Analog Current, Analog Voltage), and Temperature (-30°C ~ 100°C).

Selection Notes
  • For PT30-100PSIC-1-1-50-17-ST8, validate Termination Style (DIN EN 175301-803 Form C with 3' Cable) under the expected test conditions in your application.
  • Ensure the output type (Analog Current, Analog Voltage) is compatible with the downstream interface.
  • Confirm the operating temperature range (-30°C ~ 100°C) meets your deployment conditions.
  • Make sure Port Style (Threaded) aligns with your design targets and verification plan.
Alternates & Substitutions
  • In Pressure Sensors, Transducers, confirm that alternates preserve startup states and fault behavior so system behavior does not change quietly.
  • Confirm the physical match (packaging Tape & Box (TB)) and the operating corners (temperature -30°C ~ 100°C) so the substitution is not a hidden redesign.
  • For production substitutions, confirm traceability and documentation expectations so the alternate can be released cleanly.
  • Always compare the datasheet test conditions behind key specs (load, frequency, temperature) to avoid swapping in a part that was characterized differently.
FAQ

How do I validate sensor performance for PT30-100PSIC-1-1-50-17-ST8?
Test with real fixtures and environmental conditions, then confirm calibration, drift, and noise behavior meet your requirements.

Which Operating Pressure is specified for PT30-100PSIC-1-1-50-17-ST8?
0PSI ~ 100PSI (0kPa ~ 689.48kPa)

Can you confirm the Pressure Type for PT30-100PSIC-1-1-50-17-ST8?
Compound

Which Termination Style is listed for PT30-100PSIC-1-1-50-17-ST8?
DIN EN 175301-803 Form C with 3' Cable

Application Scenarios

When sourcing NOSHOK, Inc. PT30-100PSIC-1-1-50-17-ST8 for Pressure Sensors, Transducers, engineers typically focus on de-risking integration and keeping validation repeatable. Reliable environmental sensing enables better automation decisions and reduces operational risk. They monitor conditions such as temperature, humidity, light, gas concentration, or particulates for safety and efficiency. Pressure sensing emphasizes porting, response time, drift, and compensation so accuracy remains stable under real mechanical and thermal stress. Within agriculture, humidity and particulate sensing supports greenhouse automation where condensation is common. In indoor safety systems, gas and smoke sensing is validated for response time and long-term drift under variable airflow. Within industrial safety, gas and smoke sensing is treated as a reliability problem, so calibration and drift behavior are validated over time. In practice, within smart buildings, environmental sensors drive HVAC optimization in ceiling nodes exposed to dust and changing airflow patterns.

Compatibility Advice
  • In board-level integration, validate the real input environment and cabling so common-mode, biasing, and protection assumptions hold in the enclosure. This reduces the chance that substitutions push hidden limits.
  • In practice, check filtering and bandwidth choices so noise and latency align with the control or monitoring use-case on the assembled PCB.
  • Confirm calibration and drift behavior can be measured and repeated in production rather than inferred from typical curves before release to production.
Project Fit
  • More fragile when integrating NOSHOK, Inc. PT30-100PSIC-1-1-50-17-ST8 for Pressure Sensors, Transducers, calibration and drift cannot be supported but long-term accuracy is still expected, because integration risk stays high when key margins cannot be measured.
  • Strongest fit when you can bench-verify NOSHOK, Inc. PT30-100PSIC-1-1-50-17-ST8 for Pressure Sensors, Transducers integration in the final enclosure, typically when you can validate drift and response time in the real airflow and enclosure environment.