PT30-100psic-1-1-50-34-CC

PT30-100psic-1-1-50-34-CC

$293.58
  • Description:High Performance Fixed Range Pre
  • Series:PT30
  • Mfr:NOSHOK, Inc.
  • Package:Tape & Box (TB)

SKU:40403a03b621 Category: Brand:

  
  • Quantity
    • -
    • +
  •    
ChipApex WhatsApp

Consult the customer manager about the wholesale price.

consultation hotline:86-132-6715-2157

email:chipapexlimited@gmail.com
Contact the product manager for consultation. One-stop consultation is available.


Do you want a lower wholesale price? Please send us your inquiry and we will reply immediately.

*
*
*
*
Submitting!
Submission successful!
Submission failed!
Email error!
Phone number error!

Product Detailed Parameters

  • Description:High Performance Fixed Range Pre
  • Series:PT30
  • Mfr:NOSHOK, Inc.
  • Package:Tape & Box (TB)
  • Applications:Industrial
  • Pressure Type:Compound
  • Operating Pressure:0PSI ~ 100PSI (0kPa ~ 689.48kPa)
  • Output Type:Analog Current, Analog Voltage
  • Output:4 mA ~ 20 mA
  • Accuracy:±0.25%
  • Voltage - Supply:-
  • Port Size:Male - 7/16" (11.11mm) SAE
  • Port Style:Threaded
  • Features:-
  • Termination Style:Packard, 3 Pin
  • Operating Temperature:-30°C ~ 100°C
  • Mounting Type:-
  • Package / Case:-
  • Supplier Device Package:-
  • Grade:-
  • Qualification:-

Download product information

PT30-100psic-1-1-50-34-CC

Buying Guide
Summary

NOSHOK, Inc. PT30-100PSIC-1-1-50-34-CC is used in Pressure Sensors, Transducers category where placement, interface fit, and operating envelope drive measurement reliability. Key specs include Description (High Performance Fixed Range Pre), Output type (Analog Current, Analog Voltage), and Temperature (-30°C ~ 100°C).

Selection Notes
  • For PT30-100PSIC-1-1-50-34-CC, confirm the output type (Analog Current, Analog Voltage) and any level/threshold requirements for your system.
  • Verify the operating temperature range (-30°C ~ 100°C) and derate as needed in your application.
  • Confirm Pressure Type (Compound) is suitable for your use case and operating conditions.
Alternates & Substitutions
  • For Pressure Sensors, Transducers, validate alternates under worst-case corners rather than assuming typical-only conditions represent production builds.
  • Verify the alternate can be tested with your existing fixtures and acceptance criteria so production verification stays repeatable.
  • When evaluating alternates, treat packaging Tape & Box (TB) as non-negotiable unless you are re-spinning the PCB.
  • When in doubt, treat the swap as an ECO: define acceptance criteria, then validate under worst-case operating corners.
FAQ

Who is the manufacturer of PT30-100PSIC-1-1-50-34-CC?
NOSHOK, Inc.

How do I validate sensor performance for PT30-100PSIC-1-1-50-34-CC?
Test with real fixtures and environmental conditions, then confirm calibration, drift, and noise behavior meet your requirements.

What output type does PT30-100PSIC-1-1-50-34-CC have?
Analog Current, Analog Voltage

Which Pressure Type is specified for PT30-100PSIC-1-1-50-34-CC?
Compound

Application Scenarios

For NOSHOK, Inc. PT30-100PSIC-1-1-50-34-CC used in Pressure Sensors, Transducers designs, the shortlist is often driven by predictable margins and a straightforward validation plan. Integration often involves placement strategy, airflow considerations, and calibration workflows tied to the target environment. Reliable environmental sensing enables better automation decisions and reduces operational risk. In consumer devices, compact sensing enables adaptive control under tight power budgets. In safety and air-quality monitoring, gas and smoke sensing is qualified for drift and contamination because false alarms and misses are costly. In indoor safety systems, gas and smoke sensing is validated for response time and long-term drift under variable airflow. Pressure sensing emphasizes porting, response time, drift, and compensation so accuracy remains stable under real mechanical and thermal stress. That discipline usually improves system uptime by reducing intermittent faults and hard-to-reproduce issues.

Compatibility Advice
  • In practice, confirm calibration and compensation strategy so readings stay repeatable across production lots during bring-up and production test.
  • To reduce integration risk, confirm calibration and compensation strategy so readings stay repeatable across production lots with the final enclosure and cabling.
Project Fit
  • Most suitable when you can test and document NOSHOK, Inc. PT30-100PSIC-1-1-50-34-CC for Pressure Sensors, Transducers integration with production-like fixtures, especially if you can measure noise and interference sources so acceptance criteria are objective. That said, a weaker fit when integrating NOSHOK, Inc. PT30-100PSIC-1-1-50-34-CC for Pressure Sensors, Transducers, noise and interference sources are unknown, so the error budget cannot be bounded, because the integration depends on constraints that cannot be controlled across builds.
PT30-100psic-1-1-50-34-CCPT30-100psic-1-1-50-34-CC
$293.58
Buy Now