  • Description:High Performance Fixed Range Pre
  • Series:PT30
  • Mfr:NOSHOK, Inc.
  • Package:Tape & Box (TB)

SKU:abdf33d37bfe Category: Brand:

  
  • Quantity
    • -
    • +
  •    
ChipApex WhatsApp

Consult the customer manager about the wholesale price.

consultation hotline:86-132-6715-2157

email:chipapexlimited@gmail.com
Contact the product manager for consultation. One-stop consultation is available.


Do you want a lower wholesale price? Please send us your inquiry and we will reply immediately.

*
*
*
*
Submitting!
Submission successful!
Submission failed!
Email error!
Phone number error!

Product Detailed Parameters

  • Description:High Performance Fixed Range Pre
  • Series:PT30
  • Mfr:NOSHOK, Inc.
  • Package:Tape & Box (TB)
  • Applications:Industrial
  • Pressure Type:Compound
  • Operating Pressure:0PSI ~ 100PSI (0kPa ~ 689.48kPa)
  • Output Type:Analog Current, Analog Voltage
  • Output:4 mA ~ 20 mA
  • Accuracy:±0.25%
  • Voltage - Supply:-
  • Port Size:Male - 7/16" (11.11mm) SAE
  • Port Style:Threaded
  • Features:-
  • Termination Style:Cable 3'
  • Operating Temperature:-30°C ~ 100°C
  • Mounting Type:-
  • Package / Case:-
  • Supplier Device Package:-
  • Grade:-
  • Qualification:-

Download product information

PT30-100psic-1-1-50-36-ST8-CC

Buying Guide
Summary

NOSHOK, Inc. PT30-100PSIC-1-1-50-36-ST8-CC is selected in Pressure Sensors, Transducers category when calibration, drift, and environment constraints must be validated early. Key specs include Description (High Performance Fixed Range Pre), Output type (Analog Current, Analog Voltage), and Temperature (-30°C ~ 100°C).

Selection Notes
  • For PT30-100PSIC-1-1-50-36-ST8-CC, match the output type (Analog Current, Analog Voltage) when selecting alternates or second sources.
  • Validate the operating temperature range (-30°C ~ 100°C) for your environment and margin.
  • Make sure Operating Pressure (0PSI ~ 100PSI (0kPa ~ 689.48kPa)) aligns with your design targets and verification plan.
  • Check Port Size (Male - 7/16" (11.11mm) SAE) against the datasheet conditions and your system-level constraints.
Alternates & Substitutions
  • For Pressure Sensors, Transducers, treat alternates as an integration task and validate the assumptions that matter on the assembled system.
  • Always compare the datasheet test conditions behind key specs (load, frequency, temperature) to avoid swapping in a part that was characterized differently.
  • Start with mechanical equivalence and keep packaging Tape & Box (TB) aligned so the alternate is footprint-safe.
  • Confirm compliance/qualification needs (for example RoHS/REACH or grade) before approving a second source for production.
FAQ

Who is the manufacturer of PT30-100PSIC-1-1-50-36-ST8-CC?
NOSHOK, Inc.

What Output does PT30-100PSIC-1-1-50-36-ST8-CC have?
4 mA ~ 20 mA

What is the Termination Style of PT30-100PSIC-1-1-50-36-ST8-CC?
Cable 3'

What Applications does PT30-100PSIC-1-1-50-36-ST8-CC have?
Industrial

Application Scenarios

In real deployments, for many Pressure Sensors, Transducers designs, NOSHOK, Inc. PT30-100PSIC-1-1-50-36-ST8-CC is vetted against electrical margins, thermal headroom, and mechanical integration before the BOM is frozen. They monitor conditions such as temperature, humidity, light, gas concentration, or particulates for safety and efficiency. Designers typically evaluate response time, drift, contamination resistance, and compensation so readings stay meaningful over time. In smart buildings, environmental sensors drive HVAC optimization across dusty airflow and changing installation conditions. In smart buildings, environmental sensors drive HVAC optimization in ceiling nodes exposed to dust and changing airflow patterns. Within industrial process lines, temperature and gas monitoring protects operators near ovens, tanks, or clean rooms with strict calibration rules. In real deployments, pressure sensing emphasizes porting, response time, drift, and compensation so accuracy remains stable under real mechanical and thermal stress. That combination typically reduces re-spin risk and shortens the path to compliance and production release.

Compatibility Advice
  • During bring-up and production test, verify environmental stress assumptions (temperature, humidity, contamination) so sensing remains repeatable over life. This keeps integration from depending on typical-only conditions.
  • In qualification work, check filtering and bandwidth choices so noise, latency, and stability align with the real control loop or measurement method. This keeps integration from depending on typical-only conditions.
  • To reduce integration risk, check filtering and bandwidth choices so noise, latency, and stability align with the real control loop or measurement method. This reduces the chance that substitutions push hidden limits.
Project Fit
  • Good fit when you can measure and verify NOSHOK, Inc. PT30-100PSIC-1-1-50-36-ST8-CC for Pressure Sensors, Transducers integration across temperature and supply corners, and you need repeatable measurement behavior with a defined test plan across production lots.
  • Poor fit when test access is too limited to verify the key measurement metrics, because repeatable production verification is not feasible.
PT30-100psic-1-1-50-36-ST8-CCPT30-100psic-1-1-50-36-ST8-CC
$326.14
Buy Now