RIK-mV-1:ATR-11

RIK-mV-1:ATR-11

$352.73
  • Description:1PH 0.333 Vac INT 11" ATC COIL
  • Series:RIK
  • Mfr:Accuenergy
  • Package:Bulk

SKU:df70a49f9c0a Category: Brand:

  
  • Quantity
    • -
    • +
  •    
ChipApex WhatsApp

Consult the customer manager about the wholesale price.

consultation hotline:86-132-6715-2157

email:chipapexlimited@gmail.com
Contact the product manager for consultation. One-stop consultation is available.


Do you want a lower wholesale price? Please send us your inquiry and we will reply immediately.

*
*
*
*
Submitting!
Submission successful!
Submission failed!
Email error!
Phone number error!

Product Detailed Parameters

  • Description:1PH 0.333 Vac INT 11" ATC COIL
  • Series:RIK
  • Mfr:Accuenergy
  • Package:Bulk
  • For Measuring:AC
  • Sensor Type:Rogowski Coil
  • Current - Sensing:500A, 1000A, 2500A, 5000A, 10000A, 25000A, 50000A (Selectable)
  • Number of Channels:1
  • Output:Ratiometric, 0V ~ 0.333V
  • Sensitivity:-
  • Frequency:50/60Hz
  • Linearity:-
  • Accuracy:±1%
  • Voltage - Supply:24VDC
  • Response Time:10ms
  • Current - Supply (Max):-
  • Operating Temperature:-20°C ~ 55°C
  • Grade:-
  • Qualification:-
  • Polarization:-
  • Mounting Type:DIN Rail, Panel
  • Package / Case:-
  • Supplier Device Package:-

Download product information

RIK-mV-1:ATR-11

Buying Guide
Summary

Accuenergy RIK-MV-1ATR-11 is used in Current Sensors category where placement, interface fit, and operating envelope drive measurement reliability. Key specs include Description (1PH 0.333 Vac INT 11" ATC COIL), Temperature (-20°C ~ 55°C), and Mounting (DIN Rail, Panel).

Selection Notes
  • For RIK-MV-1ATR-11, confirm For Measuring (AC) meets your design constraints and system-level expectations.
  • Confirm the mounting type (DIN Rail, Panel) is suitable for your production flow and reliability target.
  • Check the supply current (500A, 1000A, 2500A, 5000A, 10000A, 25000A, 50000A (Selectable)) in your power budget and thermal plan.
  • Double-check the channel count (1) against your integration and test plan.
Alternates & Substitutions
  • For Current Sensors, validate alternates under worst-case corners rather than assuming typical-only conditions represent production builds.
  • For any substitution, verify the datasheet conditions behind headline specs and validate the alternate under your worst-case operating corners.
  • Validate the min/max operating conditions (supply 24VDC, temperature -20°C ~ 55°C) and keep headroom for worst-case corners.
  • When in doubt, treat the swap as an ECO: define acceptance criteria, then validate under worst-case operating corners.
FAQ

How do I validate sensor performance for RIK-MV-1ATR-11?
Test with real fixtures and environmental conditions, then confirm calibration, drift, and noise behavior meet your requirements.

Which Sensor Type is listed for RIK-MV-1ATR-11?
Rogowski Coil

What is the Response Time of RIK-MV-1ATR-11?
10ms

What Number of Channels does RIK-MV-1ATR-11 have?
1

Application Scenarios

For Accuenergy RIK-MV-1ATR-11 used in Current Sensors designs, the shortlist is often driven by predictable margins and a straightforward validation plan. Reliable environmental sensing enables better automation decisions and reduces operational risk. They monitor conditions such as temperature, humidity, light, gas concentration, or particulates for safety and efficiency. Within data centers, distributed sensing improves hot-spot detection in constrained airflow channels between racks. In safety and air-quality monitoring, gas and smoke sensing is qualified for drift and contamination because false alarms and misses are costly. In indoor safety systems, gas and smoke sensing is validated for response time and long-term drift under variable airflow. Environmental sensing focuses on drift, response time, contamination exposure, and compensation so readings remain meaningful over life.

Compatibility Advice
  • To reduce integration risk, check filtering and bandwidth choices so noise and latency align with the control or monitoring use-case. This avoids one-off tuning in production.
Project Fit
  • Good fit when you can bench-verify Accuenergy RIK-MV-1ATR-11 for Current Sensors integration on the assembled PCB, and you need repeatable readings with a defined calibration and compensation plan across lots.
  • Poor fit when test access is too limited to verify the key measurement metrics, because it becomes difficult to prove margin across production variance.
RIK-mV-1:ATR-11RIK-mV-1:ATR-11
$352.73