V23101D7A201

V23101D7A201

  • Description:RELAY GEN PURPOSE SPDT 1.25A 24V
  • Series:V23101, AXICOM
  • Mfr:TE Connectivity
  • Package:Tube

SKU:57ae01e33233 Category: Brand:

ChipApex WhatsApp

Consult the customer manager about the wholesale price.

consultation hotline:86-132-6715-2157

email:chipapexlimited@gmail.com
Contact the product manager for consultation. One-stop consultation is available.


Do you want a lower wholesale price? Please send us your inquiry and we will reply immediately.

*
*
*
*
Submitting!
Submission successful!
Submission failed!
Email error!
Phone number error!

Product Detailed Parameters

  • Description:RELAY GEN PURPOSE SPDT 1.25A 24V
  • Series:V23101, AXICOM
  • Mfr:TE Connectivity
  • Package:Tube
  • Mounting Type:Through Hole
  • Coil Voltage:24VDC
  • Contact Form:SPDT (1 Form C)
  • Contact Rating (Current):1.25 A
  • Switching Voltage:125VAC, 120VDC - Max
  • Load - Max Switching:-
  • Coil Current:18.8 mA
  • Coil Type:Non Latching
  • Features:-
  • Termination Style:PC Pin
  • Seal Rating:-
  • Coil Insulation:-
  • Must Operate Voltage:16.8 VDC
  • Must Release Voltage:2.4 VDC
  • Operate Time:7 ms
  • Release Time:5 ms
  • Operating Temperature:-40°C ~ 85°C
  • Contact Material:Silver Palladium (AgPd), Gold (Au)
  • Approval Agency:-
  • Relay Type:General Purpose
  • Grade:-
  • Qualification:-

Download product information

V23101D7A201

Buying Guide
Summary

TE Connectivity V23101D7A201 is evaluated in Signal Relays, Up to 2 Amps category where failure modes and qualification evidence matter as much as headline ratings. Key specs include Description (RELAY GEN PURPOSE SPDT 1.25A 24V), Temperature (-40°C ~ 85°C), Mounting (Through Hole), and Packaging (Tube).

Selection Notes
  • For V23101D7A201, confirm Switching Voltage (125VAC, 120VDC - Max) meets your design constraints and system-level expectations.
  • Double-check the mounting type (Through Hole) for your intended installation method.
  • Make sure the supply current (1.25 A) fits your power budget in all modes.
Alternates & Substitutions
  • For Signal Relays, Up to 2 Amps substitutions, lock footprint/pinout and operating envelope first, then verify the critical performance conditions on your hardware.
  • Lock the mechanical constraints first (mounting Through Hole, packaging Tube) before comparing performance specs.
  • Verify the alternate stays within temperature -40°C ~ 85°C across startup, load steps, and worst-case temperature.
  • For switching parts, align contact form SPDT (1 Form C), coil 24VDC, contact rating 1.25 A and validate life expectancy under your real duty cycle.
FAQ

How do I choose an alternate for V23101D7A201?
Match footprint and ratings first, then confirm operating conditions and test conditions behind key specs before approval.

What packaging is listed for V23101D7A201?
Tube

What operating temperature range is listed for V23101D7A201?
-40°C ~ 85°C

Which Termination Style is listed for V23101D7A201?
PC Pin

Application Scenarios

In many Signal Relays, Up to 2 Amps builds, TE Connectivity V23101D7A201 is reviewed for predictable behavior, supportability, and stable qualification evidence. Switching elements are typically vetted for bounce, derating, and failure behavior because those determine nuisance faults in the field. A robust switching choice reduces intermittent issues by staying stable under contamination, vibration, and repetitive surges. In automotive power routing, switching must handle inductive loads and transients while maintaining EMI margins. In practice, within emergency-stop chains, deterministic switching behavior supports safe state transitions under bounce and contamination. Within heavy machinery, switching is validated for inductive kickback and contact wear during repetitive actuator cycles. In practice, a brief worst-case sweep can show whether performance is margin-driven or tuning-driven. This is often what separates a prototype that works from a product that stays reliable in the field.

Compatibility Advice
  • For Signal Relays, Up to 2 Amps, with the real source, load, and wiring, confirm mounting and sealing align with the environment, because ingress often drives intermittent failures. This reduces the chance that substitutions push hidden limits.
  • For Signal Relays, Up to 2 Amps, confirm contact materials match the load profile so aging and corrosion remain predictable over life on the assembled PCB.
  • For Signal Relays, Up to 2 Amps, to reduce integration risk, ensure the switching element matches the load type and transient profile so inductive kick and wear are controlled. This keeps acceptance criteria measurable and repeatable.
Project Fit
  • Good fit when you can qualify TE Connectivity V23101D7A201 for Signal Relays, Up to 2 Amps integration with production-like fixtures, and you need deterministic behavior in safety, interlock, or control paths.
  • Poor fit when inductive transients are unbounded and protection is not coordinated, because the remaining risk is system-level and cannot be bounded by datasheet checks alone.
V23101D7A201V23101D7A201

Click on the inquiry