ZPI03S0600WC

ZPI03S0600WC

$4.91
  • Description:3W AC-DC POWER SUPPLY HIGH AMBIE
  • Series:ZPI03 (3W)
  • Mfr:Zettler Magnetics
  • Package:Tube

SKU:0e52e8dceba3 Category: Brand:

  
  • Quantity
    • -
    • +
  •    
ChipApex WhatsApp

Consult the customer manager about the wholesale price.

consultation hotline:86-132-6715-2157

email:chipapexlimited@gmail.com
Contact the product manager for consultation. One-stop consultation is available.


Do you want a lower wholesale price? Please send us your inquiry and we will reply immediately.

*
*
*
*
Submitting!
Submission successful!
Submission failed!
Email error!
Phone number error!

Product Detailed Parameters

  • Description:3W AC-DC POWER SUPPLY HIGH AMBIE
  • Series:ZPI03 (3W)
  • Mfr:Zettler Magnetics
  • Package:Tube
  • Type:Enclosed
  • Number of Outputs:1
  • Voltage - Input:90 ~ 264 VAC, 120 ~ 370 VDC
  • Voltage - Output 1:6V
  • Voltage - Output 2:-
  • Voltage - Output 3:-
  • Voltage - Output 4:-
  • Current - Output (Max):500mA
  • Applications:ITE (Commercial)
  • Features:Universal Input
  • Operating Temperature:-25°C ~ 80°C
  • Efficiency:85%
  • Mounting Type:Through Hole
  • Package / Case:4-DIP Module
  • Size / Dimension:0.98" L x 0.98" W x 0.63" H (25.0mm x 25.0mm x 16.0mm)
  • Approval Agency:CB, cURus, TUV, UL
  • Standard Number:62368-1
  • Power (Watts):3 W

Download product information

ZPI03S0600WC

Buying Guide
Summary

Zettler Magnetics ZPI03S0600WC is selected in AC DC Converters category when protection behavior and transient response must be validated under realistic load steps. Key specs include Description (3W AC-DC POWER SUPPLY HIGH AMBIE), Temperature (-25°C ~ 80°C), Package/case (4-DIP Module), Mounting (Through Hole), and Packaging (Tube).

Selection Notes
  • For ZPI03S0600WC, confirm Voltage - Output 1 (6V) meets your design constraints and system-level expectations.
  • Make sure the mounting type (Through Hole) matches how the part will be installed and inspected.
  • Ensure the supply current (500mA) is acceptable for battery life and thermal limits.
  • Check the efficiency (85%) under your specific load conditions to estimate thermal dissipation.
Alternates & Substitutions
  • For AC DC Converters, validate alternates under worst-case corners rather than assuming typical-only conditions represent production builds.
  • Validate the min/max operating conditions (temperature -25°C ~ 80°C) and keep headroom for worst-case corners.
  • Start by confirming the physical match (package/case 4-DIP Module, mounting Through Hole, packaging Tube) so the swap does not create a footprint risk.
  • For regulators/converters, match input range 90 ~ 264 VAC, 120 ~ 370 VDC and validate startup, protection behavior, and thermal headroom under transients.
FAQ

Can you confirm the operating temperature range for ZPI03S0600WC?
-25°C ~ 80°C

What Voltage - Output 1 is listed for ZPI03S0600WC?
6V

Which Number of Outputs is specified for ZPI03S0600WC?
1

What current consumption is specified for ZPI03S0600WC?
500mA

Application Scenarios

Zettler Magnetics ZPI03S0600WC shows up under AC DC Converters when designers want a well-bounded, datasheet-driven building block instead of a fragile board-level workaround. Engineers often evaluate efficiency, thermal rise, transient response, EMI behavior, and fault handling to protect sensitive downstream circuits. They frequently integrate protections such as OCP/OVP/UVLO/OTP and telemetry features that simplify system monitoring and compliance. Within laboratory equipment, clean rails reduce measurement drift and improve repeatability across calibration workflows. In PoE-powered equipment, robust power management ensures stable operation under cable loss, thermal constraints, and varying supply headroom. In instrumentation, clean rails reduce measurement noise so converter and analog front-end accuracy is not limited by supply ripple. A few focused measurements can reveal whether margins are real or only show up under ideal lab setups. A clean validation strategy helps prevent corner cases from escaping into production.

Compatibility Advice
  • Across temperature and supply corners, confirm the converter matches input transients and sequencing needs, including startup, brownout, and fault behavior. This keeps qualification evidence reproducible later.
  • Check thermal headroom in the final enclosure so efficiency and protection behavior remain predictable over temperature during bring-up and production test.
  • To keep validation repeatable, confirm compensation and stability with the chosen capacitor ESR so the loop stays stable across substitutions with the real source, load, and wiring.
Project Fit
  • Ideal when you can verify Zettler Magnetics ZPI03S0600WC for AC DC Converters integration with the real wiring and cabling, and you need rails that stay stable across temperature and production variance.
  • A weaker fit when integrating Zettler Magnetics ZPI03S0600WC for AC DC Converters, the input environment is unknown and protection is not defined, because the remaining risk is system-level and cannot be bounded by datasheet checks alone.
ZPI03S0600WCZPI03S0600WC